CoChat

Early detection of faults in HVAC systems using an XGBoost model with a dynamic threshold

Chakraborty, Debaditya, Elzarka, Hazem · 2019 · Energy and Buildings
Cited by 169

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

Abstract Growing demand for energy efficient buildings requires robust models to ensure efficient performance over the evolving life cycle of the building. Energy management systems can prevent energy wastage in buildings without sacrificing occupant’s comfort. However, their full capabilities have not been completely realized, partly due to their inability to quickly detect faults in HVAC systems. An accurate model and an appropriate threshold are the key factors in fault detection. The traditional method of setting a fixed threshold often leads to missed opportunities to detect faults, delayed detection of faults or false alarms. To improve the effectiveness of fault detection algorithms, we have first developed a data-driven model using extreme gradient boosting (XGBoost). We have then applied the proposed dynamic threshold method to determine occurrences of faults in real time. This method adjusts the threshold value dynamically according to the real-time moving average and moving standard deviation of the predictions. The results demonstrate the usefulness of our proposed method to detect faults early in the course. An average increase of 8.82% and 117.65%, in the F1 score, is achieved with the proposed method in comparison to the traditional fixed threshold method and an existing dynamic residual method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.enbuild.2018.12.032

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

Metadata

Authors
Chakraborty, D., & Elzarka, H.
Venue
Energy and Buildings
Publisher
Elsevier BV
Published
2019-02
Volume
185
Pages
326-344
ISSN
0378-7788 (ISSN-L)
OpenAlex
W2907978107
Cited by
169
References
20
FWCI
13.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.