Quantitative analysis of frosting characteristics at ultra-low temperatures under forced convection conditions
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Most related studies indicated that the average frost thickness decreased with an increase in air velocity, while Lee et al. presented an opposite conclusion.
“Most of the related studies indicated that the average frost thickness was decreased with an increase in air velocity [17,102,104], while Lee et al. [96] presented an opposite conclusion.”
From Frosting mechanism and behaviors on surfaces with simple geometries: A state-of-the-art literature review (2022) · cites this paper as [104]
Byun et al. indicated that the effect of air moisture content on frost layer characteristics was much more significant than air temperature, air velocity, and plate surface temperature.
“Byun et al. [104] indicated that the effect of air moisture content on frost layer characteristics was much more significant than air temperature, air velocity, and plate surface temperature.”
From Frosting mechanism and behaviors on surfaces with simple geometries: A state-of-the-art literature review (2022) · cites this paper as [104]
Cites
Frost deposition on cold surfaces
Brian, P. L. T., Reid, R. C., & Shah, Y. T. (1970) · Industrial & Engineering Chemistry Fundamentals · doi:10.1021/i160035a013 · Cited by 142 · see citing works
Dimensionless correlations of frost properties on a cold plate
Yang, D.-K., & Lee, K.-S. (2004) · International Journal of Refrigeration · doi:10.1016/s0140-7007(03)00118-x · Cited by 134 · see citing works
Self-citationAn experimental study of frost formation on cryogenic surfaces under natural convection conditions
Liu, Z., Dong, Y., & Li, Y. (2016) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2016.02.019 · Cited by 74 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Zhang, L., Song, M., Deng, S., Shen, J., & Dang, C. (2022) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.118984 · Cited by 83 · see citing works
- Authors
- Byun, S., Jeong, H., Hyeon, S., & Lee, K.-S.
- Affiliations
- Hanyang University (KR)
- Corresponding author
- Lee, Kwan-Soo
- ORCID
- Lee, Kwan-Soo
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2021-10
- Volume
- 248
- Pages
- 111186
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W3171277319
- Cited by
- 31
- References
- 3
- Citations by year
- 2026: 3 · 2025: 10 · 2024: 6 · 2023: 5 · 2022: 5 · 2021: 2
- FWCI
- 1.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Energy and Buildings (publishedVersion)
- Funders
- National Research Foundation of Korea
- Ministry of Science and ICT, South Korea (2019R1A2B5B01069426)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Keywords
- frost formation, ultralow temperature, forced convection, air-source heat pump, frost thickness, frost density, frost layer growth, heat transfer correlations, absolute humidity, Reynolds number, Fourier number, parametric study
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review