Cited by 31Refrigeration and Air Conditioning TechnologiesIcing and De-icing TechnologiesHeat Transfer and Optimization

Quantitative analysis of frosting characteristics at ultra-low temperatures under forced convection conditions

Byun, Sungjoon, Jeong, Haijun, Hyeon, Seounghwan, Lee, Kwan-Soo·2021·Energy and Buildings

Integrity signals

Registry

Crossref · 10.1016/j.enbuild.2021.111186

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Most related studies indicated that the average frost thickness decreased with an increase in air velocity, while Lee et al. presented an opposite conclusion.

    “Most of the related studies indicated that the average frost thickness was decreased with an increase in air velocity [17,102,104], while Lee et al. [96] presented an opposite conclusion.”
  • Byun et al. indicated that the effect of air moisture content on frost layer characteristics was much more significant than air temperature, air velocity, and plate surface temperature.

    “Byun et al. [104] indicated that the effect of air moisture content on frost layer characteristics was much more significant than air temperature, air velocity, and plate surface temperature.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Byun, S., Jeong, H., Hyeon, S., & Lee, K.-S.
Affiliations
Hanyang University (KR)
Corresponding author
Lee, Kwan-Soo
Venue
Energy and Buildings
Publisher
Elsevier BV
Published
2021-10
Volume
248
Pages
111186
ISSN
0378-7788 (ISSN-L)
OpenAlex
W3171277319
Cited by
31
References
3
Citations by year
2026: 3 · 2025: 10 · 2024: 6 · 2023: 5 · 2022: 5 · 2021: 2
FWCI
1.92
Type
journal article
Language
en
Open access
closed
Locations
Energy and Buildings (publishedVersion)
Funders
  • National Research Foundation of Korea
  • Ministry of Science and ICT, South Korea (2019R1A2B5B01069426)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
Keywords
frost formation, ultralow temperature, forced convection, air-source heat pump, frost thickness, frost density, frost layer growth, heat transfer correlations, absolute humidity, Reynolds number, Fourier number, parametric study

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review