Cited by 134Refrigeration and Air Conditioning TechnologiesIcing and De-icing TechnologiesHeat Transfer and Optimization

Dimensionless correlations of frost properties on a cold plate

Yang, Dong-Keun, Lee, Kwan-Soo·2004·International Journal of Refrigeration

Integrity signals

Registry

Crossref · 10.1016/s0140-7007(03)00118-x

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Yang and Lee [27] presented an experimental correlation for the average frost density as a function of the dimensionless temperature, humidity ratio, Reynolds number, and Fourier number.

    “Yang and Lee [27] presented an experimental correlation for the average frost density as a function of the dimensionless temperature, humidity ratio, Reynolds number, and Fourier number.”
  • This correlation was further developed by Yang and Lee.

    “This correlation was further developed by Yang and Lee [89].”
  • As evaluated by Léoni et al., Hermes et al. assumed that only mass diffusion occurs in the frost layer (0.5 exponents for time), contrary to Yang and Lee.

    “As evaluated by Léoni et al. [118], Hermes et al. assumed that only mass diffusion occurs in the frost layer (0.5 exponents for the time) contrary to Yang and Lee [89].”
  • Yang and Lee's correlation [40] was very much similar to Mao et al.'s correlation [36], and the difference between the two was mainly due to frosting conditions.

    “Yang and Lee ' s correlation [40] was very much similar to Mao et al. ' s correlation [36], and the difference between the two was mainly due to frosting condi­ tions.”
  • Yang and Lee [40] believed that a dimensionless temperature based on air and cold surface temperatures can be used to replace frost surface temperature, and they presented a correlation of average frost density as a function of the dimensionless temperature, air moisture content, Reynolds number and heat transfer Fourier number.

    “Yang and Lee [40] believed that a dimensionless temperature based on air and cold surface temperatures can be used to replace frost surface temperature, and they presented a correlation of average frost density as a function of the dimensionless temperature, air moisture content, Reynolds number and heat transfer Fourier number.”

Cites

Flagged first, then by citations

2 of the 19 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Yang, D.-K., & Lee, K.-S.
Affiliations
Hanyang University (KR)
Corresponding author
Lee, Kwan-Soo
Venue
International Journal of Refrigeration
Publisher
Elsevier BV
Published
2004-01
Volume
27
Issue
1
Pages
89-96
ISSN
0140-7007 (ISSN-L)
OpenAlex
W2091126511
Cited by
134
References
19
Citations by year
2026: 7 · 2025: 11 · 2024: 8 · 2023: 6 · 2022: 14 · 2021: 10 · 2020: 3 · 2019: 9 · 2018: 4 · 2017: 10 · 2016: 8 · 2015: 6 · 2014: 9 · 2013: 4 · 2012: 3
FWCI
5.35
Type
journal article
Language
en
Open access
closed
Locations
International Journal of Refrigeration (publishedVersion)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
Keywords
frost formation, dimensionless correlation, frost thickness, frost density, effective thermal conductivity, heat transfer coefficient, mass transfer coefficient, air velocity, absolute humidity, dimensional analysis, frost prediction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review