Cited by 119Heat Transfer and OptimizationAdsorption and Cooling SystemsBuilding Energy and Comfort Optimization

The DOI matches its Crossref record.

Experimental analysis of an air-to-air heat recovery unit for balanced ventilation systems in residential buildings

Fernández-Seara, José, Diz, Rubén, Uhía, Francisco J., Dopazo, Alberto, Ferro, José M.·2011·Energy Conversion and Management

Overview

Integrity signals

Registry

Crossref · 10.1016/j.enconman.2010.07.040

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 9

  1. Zhang, 2008, Heat and moisture transfer in application scale parallel-plates enthalpy exchangers with novel membrane materials, J Membr Sci, 325, 672, 10.1016/j.memsci.2008.08.041 · DOI
  2. Liddament, 1998, Technical and economical analysis of heat recovery in building ventilation systems, Appl Therm Eng, 18, 1101, 10.1016/S1359-4311(98)00040-4 · DOI
  3. Roulet, 2001, Real heat recovery with air handling units, Energy Build, 33, 495, 10.1016/S0378-7788(00)00104-3 · DOI
  4. Fehrm, 2002, Exhaust air heat recovery in buildings, Int J Refrig, 25, 439, 10.1016/S0140-7007(01)00035-4 · DOI
  5. Renato, 1998, Technical and economical analysis of heat recovery in building ventilation systems, Appl Therm Eng, 18, 47, 10.1016/S1359-4311(97)00013-6 · DOI
  6. Manz, 2000, Experimental and numerical study of a duct/heat exchanger unit for building ventilation, Energy Build, 32, 189, 10.1016/S0378-7788(00)00043-8 · DOI
  7. T’Joen, 2009, A review on polymer heat exchangers for HVAC & R applications, Int J Refrig, 32, 763, 10.1016/j.ijrefrig.2008.11.008 · DOI
  8. Kragh, 2007, New counter flow heat exchanger designed for ventilation systems in cold climates, Energy Build, 39, 1151, 10.1016/j.enbuild.2006.12.008 · DOI
  9. Hyland, 1983, Formulations for the thermodynamic properties of the saturated phases of H2O from 173.15 K to 473.15 K, ASHRAE Transactions, 89, 500

Cited by

Sorted by citations

Metadata

Authors
Fernández-Seara, J., Diz, R., Uhía, F. J., Dopazo, A., & Ferro, J. M.
Affiliations
Universidade de Vigo (ES)
Venue
Energy Conversion and Management
Publisher
Elsevier BV
Published
2011-01
Volume
52
Issue
1
Pages
635-640
ISSN
0196-8904 (ISSN-L)
OpenAlex
W2094090566
Cited by
119
References
0
Citations by year
2026: 4 · 2025: 4 · 2024: 7 · 2023: 12 · 2022: 8 · 2021: 18 · 2020: 9 · 2019: 5 · 2018: 9 · 2017: 5 · 2016: 8 · 2015: 14 · 2014: 5 · 2013: 7 · 2012: 2
FWCI
6.70
Type
journal article
Language
en
Open access
closed
Locations
Energy Conversion and Management (publishedVersion)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
Keywords
air-to-air heat recovery, balanced ventilation, residential buildings, sensible heat recovery, parametric study, air flow rate

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review