The DOI matches its Crossref record.
Experimental analysis of an air-to-air heat recovery unit for balanced ventilation systems in residential buildings
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Heat transfer rate of plate heat exchanger under condensation increases with increasing mass of condensed water due to increasing inlet humidity.
“reported that the heat transfer rate increased with increasing mass of condensed water, due to increasing inlet humidity.”
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 9
- Zhang, 2008, Heat and moisture transfer in application scale parallel-plates enthalpy exchangers with novel membrane materials, J Membr Sci, 325, 672, 10.1016/j.memsci.2008.08.041 · DOI
- Liddament, 1998, Technical and economical analysis of heat recovery in building ventilation systems, Appl Therm Eng, 18, 1101, 10.1016/S1359-4311(98)00040-4 · DOI
- Roulet, 2001, Real heat recovery with air handling units, Energy Build, 33, 495, 10.1016/S0378-7788(00)00104-3 · DOI
- Fehrm, 2002, Exhaust air heat recovery in buildings, Int J Refrig, 25, 439, 10.1016/S0140-7007(01)00035-4 · DOI
- Renato, 1998, Technical and economical analysis of heat recovery in building ventilation systems, Appl Therm Eng, 18, 47, 10.1016/S1359-4311(97)00013-6 · DOI
- Manz, 2000, Experimental and numerical study of a duct/heat exchanger unit for building ventilation, Energy Build, 32, 189, 10.1016/S0378-7788(00)00043-8 · DOI
- T’Joen, 2009, A review on polymer heat exchangers for HVAC & R applications, Int J Refrig, 32, 763, 10.1016/j.ijrefrig.2008.11.008 · DOI
- Kragh, 2007, New counter flow heat exchanger designed for ventilation systems in cold climates, Energy Build, 39, 1151, 10.1016/j.enbuild.2006.12.008 · DOI
- Hyland, 1983, Formulations for the thermodynamic properties of the saturated phases of H2O from 173.15 K to 473.15 K, ASHRAE Transactions, 89, 500
Cited by
Sorted by citations
Patil, M. S., Seo, J.-H., & Lee, M.-Y. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.11.107 · Cited by 86
EFFECT OF CONDENSATION ON THE EFFICIENCY OF HEAT RECOVERY VENTILATORS FOR BROILER HOUSES
HAN, H., NAM, S.-H., & HAN, G.-S. (2013) · International Journal of Air-Conditioning and Refrigeration · doi:10.1142/s2010132513500090 · Cited by 6
Metadata
- Authors
- Fernández-Seara, J., Diz, R., Uhía, F. J., Dopazo, A., & Ferro, J. M.
- Affiliations
- Universidade de Vigo (ES)
- ORCID
- Diz, Rubén
- Venue
- Energy Conversion and Management
- Publisher
- Elsevier BV
- Published
- 2011-01
- Volume
- 52
- Issue
- 1
- Pages
- 635-640
- ISSN
- 0196-8904 (ISSN-L)
- OpenAlex
- W2094090566
- Cited by
- 119
- References
- 0
- Citations by year
- 2026: 4 · 2025: 4 · 2024: 7 · 2023: 12 · 2022: 8 · 2021: 18 · 2020: 9 · 2019: 5 · 2018: 9 · 2017: 5 · 2016: 8 · 2015: 14 · 2014: 5 · 2013: 7 · 2012: 2
- FWCI
- 6.70
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Energy Conversion and Management (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Keywords
- air-to-air heat recovery, balanced ventilation, residential buildings, sensible heat recovery, parametric study, air flow rate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review