The DOI matches its Crossref record.
Impact of energy storage in buildings on electricity demand side management
Abstract
Abstract This paper assesses impact of using phase change materials (PCM) in buildings to leverage its thermal energy storage capability. The emphasis is from an electricity demand side perspective with case studies that incorporates wholesale electricity market data of New Zealand. The results presented in this paper show that for space heating application significant advantages could be obtained using PCM built structures. These positive impacts include peak load shifting, energy conservation and reduction in peak demand for network line companies and potential reduction in electricity consumption and savings for residential customers. This paper uses a testing facility that consists of two identically designed and shaped offices built at Tamaki Campus location of the University of Auckland, New Zealand. The walls and ceilings of one office are finished with ordinary gypsum boards while the interior of the other office is finished with PCM impregnated gypsum boards. Controlled heating facility is provided in both the offices for maintaining temperature within the range of human comfort. This facility is equipped with advanced data acquisition equipment for data monitoring and archiving both locally within the offices and also remotely. Through actual observations and analysis this paper demonstrates two major impacts of DSM. First, the application of phase change material (PCM) in building environment enabling efficient thermal storage to achieve some reduction in the overall electrical energy consumption. Second, assessment of peak load shifting achieved for space heating in a PCM building during a typical winter period in New Zealand.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Review on phase change materials (PCMs) for cold thermal energy storage applications
Oró, E., de Gracia, A., Castell, A., Farid, M. M., & Cabeza, L. F. (2012) · Applied Energy · doi:10.1016/j.apenergy.2012.03.058 · Cited by 1,144
Self-citationReview of energy storage services, applications, limitations, and benefits
AL Shaqsi, A. Z., Sopian, K., & Al-Hinai, A. (2020) · Energy Reports · doi:10.1016/j.egyr.2020.07.028 · Cited by 699
A review of potential materials for thermal energy storage in building applications
Tatsidjodoung, P., Le Pierrès, N., & Luo, L. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.10.025 · Cited by 643
Maximization of performance of a PCM latent heat storage system with innovative fins
Sciacovelli, A., Gagliardi, F., & Verda, V. (2015) · Applied Energy · doi:10.1016/j.apenergy.2014.07.015 · Cited by 603
Matos, C. R., Carneiro, J. F., & Silva, P. P. (2019) · Journal of Energy Storage · doi:10.1016/j.est.2018.11.023 · Cited by 560
Metadata
- Authors
- Qureshi, W. A., Nair, N.-K. C., & Farid, M. M.
- Venue
- Energy Conversion and Management
- Publisher
- Elsevier BV
- Published
- 2011-05
- Volume
- 52
- Issue
- 5
- Pages
- 2110-2120
- ISSN
- 0196-8904 (ISSN-L)
- OpenAlex
- W2040451577
- Cited by
- 186
- References
- 0
- FWCI
- 29.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of energy storage in buildings on electricity demand side management. https://app.cochat.ai/papers/10.1016/j.enconman.2010.12.008
- The paper
- Qureshi, W. A., Nair, N.-K. C., & Farid, M. M. (2011). Impact of energy storage in buildings on electricity demand side management. Energy Conversion and Management. https://doi.org/10.1016/j.enconman.2010.12.008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.