Application of signal processing techniques for islanding detection of distributed generation in distribution network: A review
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The wavelet transform, time-frequency localization and signal analysis
Daubechies, I. (1990) · IEEE Transactions on Information Theory · doi:10.1109/18.57199 · Cited by 6,483 · cited 1×
“It has been widely used in power system applications, such as detection, disturbance transition events in electrical power quality, feature extraction, power system protection, and de-noising [59–61].”
MethodLocalization of the complex spectrum: the S transform
Stockwell, R. G., Mansinha, L., & Lowe, R. P. (1996) · IEEE Transactions on Signal Processing · doi:10.1109/78.492555 · Cited by 3,486 · cited 1×
“It is based on a scalable localising Gaussian window, and supplies the frequency dependent resolution [78–80].”
BackgroundGraps, A. (1995) · IEEE Computational Science and Engineering · doi:10.1109/99.388960 · Cited by 1,765 · cited 1×
“It decomposes a signal into its constituents at different frequency scales [57,58].”
BackgroundPower quality assessment via wavelet transform analysis
Santoso, S., Powers, E. J., Grady, W. M., & Hofmann, P. (1996) · IEEE Transactions on Power Delivery · doi:10.1109/61.489353 · Cited by 1,022 · cited 1×
“It has been widely used in power system applications, such as detection, disturbance transition events in electrical power quality, feature extraction, power system protection, and de-noising [59–61].”
MethodPeng, Z. K., Tse, P. W., & Chu, F. L. (2005) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2004.01.006 · Cited by 840
dsp tips & tricks - the sliding DFT
Lyons, R. (2003) · IEEE Signal Processing Magazine · doi:10.1109/msp.2003.1184347 · Cited by 672 · cited 1×
“It directly calculates the amplitude and phase of the desired frequency of the input signal, which ultimately reduces the computational time [53–55].”
BackgroundJang, S.-I., & Kim, K.-H. (2004) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2003.822964 · Cited by 592
Mishra, S., Bhende, C. N., & Panigrahi, B. K. (2008) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.911125 · Cited by 532 · cited 1×
“In this tool, the sinusoid is fixed with respect to the time axis, and localised scalable Gaussian window examined it more comprehensively by dilating and translating the phase frequency [81,82].”
MethodPower quality analysis using s-transform
Dash, P. K., Panigrahi, B. K., & Panda, G. (2003) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2003.809616 · Cited by 511
Comparative Analysis Between ROCOF and Vector Surge Relays for Distributed Generation Applications
Freitas, W., Xu, W., Affonso, C. M., & Huang, Z. (2005) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2004.834869 · Cited by 377 · cited 1×
“Some of the most common passive techniques are the rate of change of power (ROCOP) [7], rate of change of frequency (ROCOF) [19–21], rate of change of frequency over power (ROCOFOP) [22], change of impedance [23], voltage unbalance [24], over/under (O/U) voltage and over/under frequency [25], harmonic distortion (volt…”
Background
Cited by
Grid-connected isolated PV microinverters: A review
Hasan, R., Mekhilef, S., Seyedmahmoudian, M., & Horan, B. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.09.082 · Cited by 202
AC microgrid protection – A review: Current and future prospective
Patnaik, B., Mishra, M., Bansal, R. C., & Jena, R. K. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.115210 · Cited by 166
Metadata
- Authors
- Raza, S., Mokhlis, H., Arof, H., Laghari, J. A., & Wang, L.
- Venue
- Energy Conversion and Management
- Publisher
- Elsevier BV
- Published
- 2015-05
- Volume
- 96
- Pages
- 613-624
- ISSN
- 0196-8904 (ISSN-L)
- OpenAlex
- W2085843260
- Cited by
- 190
- References
- 45
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.