The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Towards accurate CFD simulations of vertical axis wind turbines at different tip speed ratios and solidities: Guidelines for azimuthal increment, domain size and convergence
Open accessAbstract
The accuracy of CFD simulations of vertical axis wind turbines (VAWTs) is known to be significantly associated with the computational parameters, such as azimuthal increment, domain size and number of turbine revolutions before reaching a statistically steady state condition (convergence). A detailed review of the literature, however, indicates that there is a lack of extensive parametric studies investigating the impact of the computational parameters. The current study, therefore, intends to systematically investigate the impact of these parameters, on the simulation results to guide the execution of accurate CFD simulations of VAWTs at different tip speed ratios (λ) and solidities (σ). The evaluation is based on 110 CFD simulations validated with wind-tunnel measurements for two VAWTs. Instantaneous moment coefficient, Cm, and power coefficient, CP, are studied for each case using unsteady Reynolds-averaged Navier-Stokes (URANS) simulations with the 4-equation transition SST turbulence model. The results show that the azimuthal increment dθ is largely dependent on tip speed ratio. For moderate to high λ, the minimum requirement for dθ is 0.5° while this decreases to 0.1° at low to moderate λ. The need for finer time steps is associated to the flow complexities related to dynamic stall on turbine blades and blade-wake interactions at low λ. In addition, the minimum distance from the turbine center to the domain inlet and outlet is 15 and 10 times the turbine diameter, respectively. It is also shown that 20–30 turbine revolutions are required to ensure statistically converged solutions. The current findings can serve as guidelines towards accurate and reliable CFD simulations of VAWTs at different tip speed ratios and solidities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-equation eddy-viscosity turbulence models for engineering applications
Menter, F. R. (1994) · AIAA Journal · doi:10.2514/3.12149 · Cited by 21,593
Cited by
On the accuracy of turbulence models for CFD simulations of vertical axis wind turbines
Rezaeiha, A., Montazeri, H., & Blocken, B. (2019) · Energy · doi:10.1016/j.energy.2019.05.053 · Cited by 380
Self-citation
Metadata
- Authors
- Rezaeiha, A., Montazeri, H., & Blocken, B.
- Venue
- Energy Conversion and Management
- Publisher
- Elsevier BV
- Published
- 2018-01
- Volume
- 156
- Pages
- 301-316
- ISSN
- 0196-8904 (ISSN-L)
- OpenAlex
- W2774343323
- Cited by
- 218
- References
- 1
- FWCI
- 18.25
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Towards accurate CFD simulations of vertical axis wind turbines at different tip speed ratios and solidities: Guidelines for azimuthal increment, domain size and convergence. https://app.cochat.ai/papers/10.1016/j.enconman.2017.11.026
- The paper
- Rezaeiha, A., Montazeri, H., & Blocken, B. (2018). Towards accurate CFD simulations of vertical axis wind turbines at different tip speed ratios and solidities: Guidelines for azimuthal increment, domain size and convergence. Energy Conversion and Management. https://doi.org/10.1016/j.enconman.2017.11.026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.