CoChat
Cited by 218

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Towards accurate CFD simulations of vertical axis wind turbines at different tip speed ratios and solidities: Guidelines for azimuthal increment, domain size and convergence

Open access
Rezaeiha, Abdolrahim, Montazeri, Hamid, Blocken, Bert · 2018 · Energy Conversion and Management

Abstract

The accuracy of CFD simulations of vertical axis wind turbines (VAWTs) is known to be significantly associated with the computational parameters, such as azimuthal increment, domain size and number of turbine revolutions before reaching a statistically steady state condition (convergence). A detailed review of the literature, however, indicates that there is a lack of extensive parametric studies investigating the impact of the computational parameters. The current study, therefore, intends to systematically investigate the impact of these parameters, on the simulation results to guide the execution of accurate CFD simulations of VAWTs at different tip speed ratios (λ) and solidities (σ). The evaluation is based on 110 CFD simulations validated with wind-tunnel measurements for two VAWTs. Instantaneous moment coefficient, Cm, and power coefficient, CP, are studied for each case using unsteady Reynolds-averaged Navier-Stokes (URANS) simulations with the 4-equation transition SST turbulence model. The results show that the azimuthal increment dθ is largely dependent on tip speed ratio. For moderate to high λ, the minimum requirement for dθ is 0.5° while this decreases to 0.1° at low to moderate λ. The need for finer time steps is associated to the flow complexities related to dynamic stall on turbine blades and blade-wake interactions at low λ. In addition, the minimum distance from the turbine center to the domain inlet and outlet is 15 and 10 times the turbine diameter, respectively. It is also shown that 20–30 turbine revolutions are required to ensure statistically converged solutions. The current findings can serve as guidelines towards accurate and reliable CFD simulations of VAWTs at different tip speed ratios and solidities.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.enconman.2017.11.026

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 218

Metadata

Authors
Rezaeiha, A., Montazeri, H., & Blocken, B.
Venue
Energy Conversion and Management
Publisher
Elsevier BV
Published
2018-01
Volume
156
Pages
301-316
ISSN
0196-8904 (ISSN-L)
OpenAlex
W2774343323
Cited by
218
References
1
FWCI
18.25
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Towards accurate CFD simulations of vertical axis wind turbines at different tip speed ratios and solidities: Guidelines for azimuthal increment, domain size and convergence. https://app.cochat.ai/papers/10.1016/j.enconman.2017.11.026
The paper
Rezaeiha, A., Montazeri, H., & Blocken, B. (2018). Towards accurate CFD simulations of vertical axis wind turbines at different tip speed ratios and solidities: Guidelines for azimuthal increment, domain size and convergence. Energy Conversion and Management. https://doi.org/10.1016/j.enconman.2017.11.026

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.