Formulation of a model predictive control algorithm to enhance the performance of a latent heat solar thermal system
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Abstract Model predictive control has proved to be a promising control strategy for improving the operational performance of multi-source thermal energy generation systems with the aim of maximising the exploitation of on-site renewable resources. This paper presents the formulation and implementation of a model predictive control strategy for the management of a latent heat thermal energy storage unit coupled with a solar thermal collector and a backup electric heater. The system uses an innovative Phase Change Material slurry for both the heat transfer fluid and storage media. The formulation of a model predictive controller of such a closed-loop solar system is particularly desirable but also challenging mainly due to the nonlinearity of the heat exchange and thermal storage processes involved. A solution for the model predictive control problem to regulate a system with intrinsic nonlinearities is introduced using a mixed logic-dynamical approach. The model predictive control regulation is tested and compared with a baseline rule-based controller considering both ideal and estimated disturbance predictions. Results demonstrate the capability of the predictive controller in anticipating future disturbances and in optimising the utilisation of the more efficient energy sources. When compared to the rule-based controller, the model predictive control algorithm leads to reductions of the system primary energy demand ranging from 19.2% to 31.8% as a function of the variation of a soft constraint on meeting demand constraints. The work contributes to new knowledge on how model predictive control algorithms can be implemented to maximise the benefits of integrating thermal energy storages that employ latent heat of fusion with solar thermal technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heat and cold storage with PCM: An up to date introduction into basics and applications
Mehling, H., & Cabeza, L. F. (2008) · Heat and Mass Transfer · doi:10.1007/978-3-540-68557-9 · Cited by 894
Serale, G., Fiorentini, M., Capozzoli, A., Bernardini, D., & Bemporad, A. (2018) · Energies · doi:10.3390/en11030631 · Cited by 637
Self-citationTen Questions Concerning Model Predictive Control for Energy Efficient Buildings
Killian, M., & Kozek, M. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.05.034 · Cited by 463
Approximate model predictive building control via machine learning
Drgoňa, J., Picard, D., Kvasnica, M., & Helsen, L. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.02.156 · Cited by 260
An integrated system for buildings’ energy-efficient automation: Application in the tertiary sector
Marinakis, V., Doukas, H., Karakosta, C., & Psarras, J. (2013) · Applied Energy · doi:10.1016/j.apenergy.2012.05.032 · Cited by 154
Cited by
Kılkış, Ş., Krajačić, G., Duić, N., Rosen, M. A., & Al-Nimr, M. A. (2020) · Energy Conversion and Management · doi:10.1016/j.enconman.2020.113410 · Cited by 116
Characteristic of thermal energy system self-driven by exhausted heat from equipment in lunar base
Zhang, K., Sun, P., Li, S., Spataru, C., Lv, X., & Weng, Y. (2022) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.118751 · Cited by 18
Liu, M., Chen, W.-A., Gao, Y., & Hu, Z. (2025) · Sustainability · doi:10.3390/su17219497 · Cited by 9
Metadata
- Authors
- Serale, G., Fiorentini, M., Capozzoli, A., Cooper, P., & Perino, M.
- Venue
- Energy Conversion and Management
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 173
- Pages
- 438-449
- ISSN
- 0196-8904 (ISSN-L)
- OpenAlex
- W2887249781
- Cited by
- 57
- References
- 5
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.