The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Thermodynamic and economic investigation of a novel integration of the absorption-recompression refrigeration system with compressed air energy storage (CAES)
Abstract
In this work, a novel hybrid system based on absorption-recompression refrigeration system, compressed air energy storage (CAES) and wind turbines is proposed for using in retail buildings. In proposed system, wind turbines are employed to provide electricity during off-peak hours. Using conventional environmental pollutant combustion chambers and refrigerants in CAES and refrigeration subsystems have been eliminated in present system. So, it is an entirely environmentally-friendly system. By tailoring a booster vapor compressor between the generator and condenser of the conventional absorption cycle and achieving full heat transfer between them, the efficiency has been significantly improved. To override the further energy consumption of the vapor compressor, coupling with a CAES system is investigated. Energy, exergy, economic and parametric investigations are applied to the proposed system and its single parts to have a comprehensive evaluation. As a result, 2287 kW cooling capacity, 2.431 total coefficient of performance and 56.71% roundtrip efficiency (RTE) are reached. The results indicate that the payback period of the proposed system is less than 6 years and 187.65 $ is saved in each cycle of the hybrid system. Furthermore, the exergy analysis represents that the pressure regulating valve in CAES and condenser/generator in refrigeration subsystems have the maximum exergy destruction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Progress in electrical energy storage system: a critical review
Chen, H., Cong, T. N., Yang, W., Tan, C., Li, Y., & Ding, Y. (2009) · Progress in Natural Science · doi:10.1016/j.pnsc.2008.07.014 · Cited by 3,746
Cited by
Critical review of energy storage systems
Olabi, A. G., Onumaegbu, C., Wilberforce, T., Ramadan, M., Abdelkareem, M. A., & Al – Alami, A. H. (2021) · Energy · doi:10.1016/j.energy.2020.118987 · Cited by 793
Compressed air energy storage in integrated energy systems: A review
Bazdar, E., Sameti, M., Nasiri, F., & Haghighat, F. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.112701 · Cited by 431
Alirahmi, S. M., Razmi, A. R., & Arabkoohsar, A. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.110850 · Cited by 298
Self-citationXue, X., Lv, J., Chen, H., Xu, G., & Li, Q. (2022) · Energy · doi:10.1016/j.energy.2022.125367 · Cited by 44
Metadata
- Authors
- Razmi, A., Soltani, M., Aghanajafi, C., & Torabi, M.
- Venue
- Energy Conversion and Management
- Publisher
- Elsevier BV
- Published
- 2019-05
- Volume
- 187
- Pages
- 262-273
- ISSN
- 0196-8904 (ISSN-L)
- OpenAlex
- W2922866867
- Cited by
- 242
- References
- 1
- FWCI
- 15.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.