Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 312

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Heat transfer reduction in buildings by embedding phase change material in multi-layer walls: Effects of repositioning, thermophysical properties and thickness of PCM

Li, Z.X., Al-Rashed, Abdullah A.A.A., Rostamzadeh, Mahfouz, Kalbasi, Rasool, Shahsavar, Amin, Afrand, Masoud·2019·Energy Conversion and Management

Abstract

Abstract Passive latent heat thermal energy storage approach incorporating phase change materials (PCM) is a brilliant technique to tackle high energy consumption issue in buildings. This paper investigated the thermal performance of the conventional walls of buildings in Isfahan, Iran with the inclusion of thirteen different phase change materials. The studied base wall was composed of plaster (2 cm), clay brick (15 cm), and cement (3 cm). The effect of PCM position inside the wall on the heat transfer was assessed in two scenarios, namely: close to the interior and close to exterior. The nonlinear governing equations were solved using the finite volume method. The results show that the performance of PCM-based wall is strongly influenced by the thermal conductivity, phase-change enthalpy and melting temperature of PCM. A PCM can more efficiently reduce the heat transfer to the interior space in case it has a lower thermal conductivity, has a higher latent heat of phase-change, and its phase-change temperature is closer to the room temperature. Moreover, the thermal conductivity has priority over other PCM thermophysical properties. The lower PCM thermal conductivity leads to transfer the lower amount of heat to the interior space. A two-fold increase in the thickness of the PCM leads to less than a twofold reduction in the heat transfer. Among the studied PCMs, the heat transfer reduction by Enerciel 22 was within the range 15.6–47.6%, while this range was 2–7.8% for CaC l 2 . 6 H 2 O .

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.enconman.2019.04.075

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 36 references

Cited by

See all 312

Metadata

Authors
Li, Z. X., Al-Rashed, A. A. A. A., Rostamzadeh, M., Kalbasi, R., Shahsavar, A., & Afrand, M.
Venue
Energy Conversion and Management
Publisher
Elsevier BV
Published
2019-09
Volume
195
Pages
43-56
ISSN
0196-8904 (ISSN-L)
OpenAlex
W2944602173
Cited by
312
References
36
FWCI
23.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Heat transfer reduction in buildings by embedding phase change material in multi-layer walls: Effects of repositioning, thermophysical properties and thickness of PCM. https://app.cochat.ai/papers/10.1016/j.enconman.2019.04.075
The paper
Li, Z. X., Al-Rashed, A. A. A. A., Rostamzadeh, M., Kalbasi, R., Shahsavar, A., & Afrand, M. (2019). Heat transfer reduction in buildings by embedding phase change material in multi-layer walls: Effects of repositioning, thermophysical properties and thickness of PCM. Energy Conversion and Management. https://doi.org/10.1016/j.enconman.2019.04.075

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.