Heat transfer reduction in buildings by embedding phase change material in multi-layer walls: Effects of repositioning, thermophysical properties and thickness of PCM
Abstract
Abstract Passive latent heat thermal energy storage approach incorporating phase change materials (PCM) is a brilliant technique to tackle high energy consumption issue in buildings. This paper investigated the thermal performance of the conventional walls of buildings in Isfahan, Iran with the inclusion of thirteen different phase change materials. The studied base wall was composed of plaster (2 cm), clay brick (15 cm), and cement (3 cm). The effect of PCM position inside the wall on the heat transfer was assessed in two scenarios, namely: close to the interior and close to exterior. The nonlinear governing equations were solved using the finite volume method. The results show that the performance of PCM-based wall is strongly influenced by the thermal conductivity, phase-change enthalpy and melting temperature of PCM. A PCM can more efficiently reduce the heat transfer to the interior space in case it has a lower thermal conductivity, has a higher latent heat of phase-change, and its phase-change temperature is closer to the room temperature. Moreover, the thermal conductivity has priority over other PCM thermophysical properties. The lower PCM thermal conductivity leads to transfer the lower amount of heat to the interior space. A two-fold increase in the thickness of the PCM leads to less than a twofold reduction in the heat transfer. Among the studied PCMs, the heat transfer reduction by Enerciel 22 was within the range 15.6–47.6%, while this range was 2–7.8% for CaC l 2 . 6 H 2 O .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Voller, V. R., & Prakash, C. (1987) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(87)90317-6 · Cited by 2,652
Materials used as PCM in thermal energy storage in buildings: A review
Cabeza, L. F., Castell, A., Barreneche, C., de Gracia, A., & Fernández, A. I. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2010.11.018 · Cited by 1,889
Use of microencapsulated PCM in concrete walls for energy savings
Cabeza, L. F., Castellón, C., Nogués, M., Medrano, M., Leppers, R., & Zubillaga, O. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2006.03.030 · Cited by 889
An enthalpy method for convection/diffusion phase change
Voller, V. R., Cross, M., & Markatos, N. C. (1987) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.1620240119 · Cited by 702
Du, K., Calautit, J., Wang, Z., Wu, Y., & Liu, H. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.03.005 · Cited by 688
A review on phase-change materials: Mathematical modeling and simulations
Dutil, Y., Rousse, D. R., Salah, N. B., Lassue, S., & Zalewski, L. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2010.06.011 · Cited by 676
Kalnæs, S. E., & Jelle, B. P. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.02.023 · Cited by 585
Phase change material (PCM) storage for free cooling of buildings—A review
Waqas, A., & Ud Din, Z. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.10.034 · Cited by 532
Thermal performance of a solar-aided latent heat store used for space heating by heat pump
Esen, M. (2000) · Solar Energy · doi:10.1016/s0038-092x(00)00015-3 · Cited by 513
Esen, M., Durmuş, A., & Durmuş, A. (1998) · Solar Energy · doi:10.1016/s0038-092x(97)00104-7 · Cited by 480
Experimental assessment of a phase change material for wall building use
Kuznik, F., & Virgone, J. (2009) · Applied Energy · doi:10.1016/j.apenergy.2009.01.004 · Cited by 435
Esen, M., & Ayhan, T. (1996) · Energy Conversion and Management · doi:10.1016/0196-8904(96)00035-0 · Cited by 429
Sun, Y., Wang, S., Xiao, F., & Gao, D. (2013) · Energy Conversion and Management · doi:10.1016/j.enconman.2013.03.026 · Cited by 358
Energetic efficiency of room wall containing PCM wallboard: A full-scale experimental investigation
Kuznik, F., Virgone, J., & Roux, J.-J. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.01.022 · Cited by 322
Pasupathy, A., Athanasius, L., Velraj, R., & Seeniraj, R. V. (2007) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2007.04.016 · Cited by 297
Numerical analysis on thermal performance of roof contained PCM of a single residential building
Li, D., Zheng, Y., Liu, C., & Wu, G. (2015) · Energy Conversion and Management · doi:10.1016/j.enconman.2015.05.014 · Cited by 278
Impact of phase change wall room on indoor thermal environment in winter
Shilei, L., Neng, Z., & Guohui, F. (2006) · Energy and Buildings · doi:10.1016/j.enbuild.2005.02.007 · Cited by 232
Novel concept of composite phase change material wall system for year-round thermal energy savings
Diaconu, B., & Cruceru, M. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.05.012 · Cited by 221
On the importance of the location of PCMs in building walls for enhanced thermal performance
Jin, X., Medina, M. A., & Zhang, X. (2013) · Applied Energy · doi:10.1016/j.apenergy.2012.12.079 · Cited by 216
Mechanical and thermo-physical behaviour of concretes and mortars containing phase change material
Lecompte, T., Le Bideau, P., Glouannec, P., Nortershauser, D., & Le Masson, S. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.02.044 · Cited by 216
Temperature reduction due to the application of phase change materials
Voelker, C., Kornadt, O., & Ostrý, M. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2007.07.008 · Cited by 214
Marin, P., Saffari, M., de Gracia, A., Zhu, X., Farid, M. M., Cabeza, L. F., & Ushak, S. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.08.007 · Cited by 210
A numerical study of external building walls containing phase change materials (PCM)
Izquierdo-Barrientos, M. A., Belmonte, J. F., Rodríguez-Sánchez, D., Molina, A. E., & Almendros-Ibáñez, J. A. (2012) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2012.02.038 · Cited by 189
Application of PCM energy storage in combination with night ventilation for space cooling
Barzin, R., Chen, J. J. J., Young, B. R., & Farid, M. M. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.08.088 · Cited by 188
Mandilaras, I. D., Stamatiadou, M., Katsourinis, D. I., Zannis, G., & Founti, M. A. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.12.007 · Cited by 174
Yao, C., Kong, X., Li, Y., Du, Y., & Qi, C. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2017.10.052 · Cited by 170
Zwanzig, S. D., Lian, Y., & Brehob, E. G. (2013) · Energy Conversion and Management · doi:10.1016/j.enconman.2013.02.003 · Cited by 166
Harikrishnan, S., Deenadhayalan, M., & Kalaiselvam, S. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.06.042 · Cited by 128
Adjustment of thermal behavior by changing the shape of PCM inclusions in concrete blocks
Erlbeck, L., Schreiner, P., Schlachter, K., Dörnhofer, P., Fasel, F., Methner, F., & Rädle, M. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2017.12.073 · Cited by 98
Zhou, G., Zhang, Y., Zhang, Q., et al. (2007) · Applied Energy · doi:10.1016/j.apenergy.2006.09.015 · Cited by 86
KUSAMA, Y., & Ishidoya, Y. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.02.033 · Cited by 71
Lee, K. O., & Medina, M. A. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2015.12.012 · Cited by 67
Akeiber, H. J., Hosseini, S. E., Hussen, H. M., Wahid, M. B. A., & Mohammad, A. T. (2017) · Energy Conversion and Management · doi:10.1016/j.enconman.2017.07.043 · Cited by 59
Geocooling with integrated PCM thermal energy storage in a commercial building
McKenna, P., Turner, W. J. N., & Finn, D. (2017) · Energy · doi:10.1016/j.energy.2017.12.029 · Cited by 54
Hembade, L. B., Neithalath, N., & Rajan, S. D. (2013) · Journal of Energy Engineering · doi:10.1061/(asce)ey.1943-7897.0000146 · Cited by 31
Zhang, Y., Wang, X., Zhang, Y., & Zhuo, S. (2016) · Energy · doi:10.1016/j.energy.2016.08.062 · Cited by 22
Cited by
Wang, X., Li, W., Luo, Z., Wang, K., & Shah, S. P. (2022) · Energy and Buildings · doi:10.1016/j.enbuild.2022.111923 · Cited by 493
Al-Yasiri, Q., & Szabó, M. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2020.102122 · Cited by 432
Nano-enhanced phase change materials: Fundamentals and applications
Said, Z., Pandey, A. K., Tiwari, A. K., Kalidasan, B., Jamil, F., Thakur, A. K., Tyagi, V. V., Sarı, A., & Ali, H. M. (2024) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2024.101162 · Cited by 386
Chen, X., Gao, H., Tang, Z., Dong, W., Li, A., & Wang, G. (2020) · Energy & Environmental Science · doi:10.1039/d0ee01355b · Cited by 348
Thermophysical properties and applications of nano-enhanced PCMs: An update review
Yang, L., Huang, J.-N., & Zhou, F. (2020) · Energy Conversion and Management · doi:10.1016/j.enconman.2020.112876 · Cited by 343
Metadata
- Authors
- Li, Z. X., Al-Rashed, A. A. A. A., Rostamzadeh, M., Kalbasi, R., Shahsavar, A., & Afrand, M.
- Venue
- Energy Conversion and Management
- Publisher
- Elsevier BV
- Published
- 2019-09
- Volume
- 195
- Pages
- 43-56
- ISSN
- 0196-8904 (ISSN-L)
- OpenAlex
- W2944602173
- Cited by
- 312
- References
- 36
- FWCI
- 23.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.