Energy savings due to the use of PCM for relocatable lightweight buildings passive heating and cooling in different weather conditions
Open accessAbstract
Relocatable, transportable or off-site constructed lightweight buildings typically undergo sharp indoor temperature fluctuations in the heating and cooling seasons due to the lack of sufficient thermal mass in their envelopes, resulting in high energy consumption to provide the zone with comfort temperature. The application of phase change materials has been suggested as a promising solution to control the indoor thermal condition in buildings. This work is an attempt to support the application of PCM technology in lightweight relocatable buildings as a passive alternative to save energy under different weather conditions. The numerical results highlighted the potential of using PCM-enhanced gypsum boards in lightweight buildings to increase the energy performance during both heating and cooling seasons in arid and warm temperate main climate areas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Updated world map of the Köppen-Geiger climate classification
Peel, M. C., Finlayson, B. L., & McMahon, T. A. (2007) · doi:10.5194/hessd-4-439-2007 · Cited by 13,640
World map of the Köppen-Geiger climate classification updated
Kottek, M., Grieser, J., Beck, C., Rudolf, B., & Rubel, F. (2006) · Meteorologische Zeitschrift · doi:10.1127/0941-2948/2006/0130 · Cited by 11,456
A review on buildings energy consumption information
Pérez-Lombard, L., Ortiz, J., & Pout, C. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.03.007 · Cited by 6,649
Heat and cold storage with PCM: An up to date introduction into basics and applications
Mehling, H., & Cabeza, L. F. (2008) · Heat and Mass Transfer · doi:10.1007/978-3-540-68557-9 · Cited by 894
Self-citationEnergy saving potential of phase change materials in major Australian cities
Alam, M., Jamil, H., Sanjayan, J., & Wilson, J. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.04.027 · Cited by 238
Sage-Lauck, J. S., & Sailor, D. J. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.04.028 · Cited by 166
Cited by
Faraj, K., Khaled, M., Faraj, J., Hachem, F., & Castelain, C. (2021) · Journal of Energy Storage · doi:10.1016/j.est.2020.101913 · Cited by 354
Saffari, M., de Gracia, A., Fernández, C., & Cabeza, L. F. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.05.107 · Cited by 343
Self-citationArıcı, M., Bilgin, F., Nižetić, S., & Karabay, H. (2020) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2019.114560 · Cited by 324
Li, Z. X., Al-Rashed, A. A. A. A., Rostamzadeh, M., Kalbasi, R., Shahsavar, A., & Afrand, M. (2019) · Energy Conversion and Management · doi:10.1016/j.enconman.2019.04.075 · Cited by 312
Optical and thermal performance of glazing units containing PCM in buildings: a review
Li, D., Wu, Y., Wang, B., Liu, C., & Arıcı, M. (2020) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2019.117327 · Cited by 216
Metadata
- Authors
- Marin, P., Saffari, M., de Gracia, A., Zhu, X., Farid, M. M., Cabeza, L. F., & Ushak, S.
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2016-10
- Volume
- 129
- Pages
- 274-283
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W2487864400
- Cited by
- 210
- References
- 6
- FWCI
- 17.41
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Energy savings due to the use of PCM for relocatable lightweight buildings passive heating and cooling in different weather conditions. https://app.cochat.ai/papers/10.1016/j.enbuild.2016.08.007
- The paper
- Marin, P., Saffari, M., de Gracia, A., Zhu, X., Farid, M. M., Cabeza, L. F., & Ushak, S. (2016). Energy savings due to the use of PCM for relocatable lightweight buildings passive heating and cooling in different weather conditions. Energy and Buildings. https://doi.org/10.1016/j.enbuild.2016.08.007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.