Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 160

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Cooling control of thermally-induced thermal runaway in 18,650 lithium ion battery with water mist

Liu, Tong, Liu, Yangpeng, Wang, Xishi, Kong, Xiangxiao, Li, Guochun · 2019 · Energy Conversion and Management

Abstract

Abstract Lithium ion battery (LIB) thermal runaway (TR) has always been a potential risk that could result in serious damage. This likelihood has increased owing to the widespread application of LIBs, particularly in the electric-vehicle industry. Therefore, an effective method must be determined to prevent or mitigate this hazardous process. As a clean and efficient cooling technique, the effect of water mist (WM) on TR has been investigated through a series of tests in this study. Batteries with various states of charge (SOC) were heated with an electric heater to induce TR, and the surface temperatures were measured throughout the tests. The results show that TR can be controlled when the WM is released before the critical temperature is reached; the threshold temperature is at least 20 °C lower than the temperature of the TR onset. The determined conservative temperature for the WM application is 186.5 °C. At 25% SOC, the critical WM cooling rate is 1.87 times that of the critical heating rate. The value increases to 4.98 at 100% SOC, thereby indicating the increasing suppression difficulty with increasing SOC. Above the critical temperature, the TR is unstoppable. However, the maximal surface temperature can be controlled at values approximately 300 °C lower than those of the cases without WM. This is beneficial for the prevention of the TR propagation. TR can still be a potential risk for suppressed batteries. Nevertheless, the thermal hazard is mitigated with increasing onset temperature and a longer heating process. This study can contribute significant results for the control of TR in practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.enconman.2019.111969

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 160

Metadata

Authors
Liu, T., Liu, Y., Wang, X., Kong, X., & Li, G.
Venue
Energy Conversion and Management
Publisher
Elsevier BV
Published
2019-11
Volume
199
Pages
111969
ISSN
0196-8904 (ISSN-L)
OpenAlex
W2971262714
Cited by
160
References
1
FWCI
7.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cooling control of thermally-induced thermal runaway in 18,650 lithium ion battery with water mist. https://app.cochat.ai/papers/10.1016/j.enconman.2019.111969
The paper
Liu, T., Liu, Y., Wang, X., Kong, X., & Li, G. (2019). Cooling control of thermally-induced thermal runaway in 18,650 lithium ion battery with water mist. Energy Conversion and Management. https://doi.org/10.1016/j.enconman.2019.111969

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.