Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 261

The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.

Pyrolysis of water hyacinth biomass parts: Bioenergy, gas emissions, and by-products using TG-FTIR and Py-GC/MS analyses

Huang, Hongyi, Liu, Jingyong, Liu, Hui, Evrendilek, Fatih, Buyukada, Musa · 2020 · Energy Conversion and Management

Abstract

This study aimed to quantify the pyrolytic bioenergy potential of water hyacinth roots (WHR), stems and leaves (WHSL) by assessing their physicochemical properties, pyrolysis performances, kinetics, and thermodynamics. Their gas emissions and other by-products were also detected using thermogravimetry-Fourier transform infrared spectroscopy and pyrolysis–gas chromatography/mass spectrometry analyses. The WHR and WHSL pyrolysis consisted of the three consecutive stages of the moisture removal, devolatilization, and the decomposition of residuals. The main pyrolysis temperature varied between 200 and 600 °C. The elevated heating rate raised both initial devolatilization and peak temperatures and shortened the reaction times of the thermochemical conversions of both samples. According to the comprehensive pyrolysis index, WHSL outperformed WHR. The average activation energy estimates pointed to a lower decomposition cost for WHSL (172.09–173.09 kJ/mol) than WHR (230.11–232.06 kJ/mol). The fluctuating thermodynamic parameters indicated a complicated pyrolysis mechanism for WHR and WHSL. The main gases evolved from the WHR and WHSL pyrolysis in decreasing order were CO2, C O, C–O, SO2, C C, H2O, CH4, and CO. The main pyrolytic by-products were phenols (19.2%), and furans (12.4%) for WHR and nitrides (11.9%), and phenols (10%) for WHSL. Our results provide insights into scaling-up bioenergy potential, value-added by-products, and emission controls based on the pyrolysis of the water hyacinth biomass parts.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.enconman.2020.112552

Cites

61 of 61 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 61 references

Cited by

See all 261

Metadata

Authors
Huang, H., Liu, J., Liu, H., Evrendilek, F., & Buyukada, M.
Venue
Energy Conversion and Management
Publisher
Elsevier BV
Published
2020-03
Volume
207
Pages
112552
ISSN
0196-8904 (ISSN-L)
OpenAlex
W3005395523
Cited by
261
References
61
FWCI
11.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pyrolysis of water hyacinth biomass parts: Bioenergy, gas emissions, and by-products using TG-FTIR and Py-GC/MS analyses. https://app.cochat.ai/papers/10.1016/j.enconman.2020.112552
The paper
Huang, H., Liu, J., Liu, H., Evrendilek, F., & Buyukada, M. (2020). Pyrolysis of water hyacinth biomass parts: Bioenergy, gas emissions, and by-products using TG-FTIR and Py-GC/MS analyses. Energy Conversion and Management. https://doi.org/10.1016/j.enconman.2020.112552

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.