Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 352

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

On the root mean square error (RMSE) calculation for parameter estimation of photovoltaic models: A novel exact analytical solution based on Lambert W function

Ćalasan, Martin, Abdel Aleem, Shady H.E., Zobaa, Ahmed F.·2020·Energy Conversion and Management

Abstract

Abstract In the literature, one can find a lot of methods and techniques employed to estimate single diode solar photovoltaic (PV) cell parameters. The efficiency of these methods is usually tested by calculating the Root Mean Square Error (RMSE) between the measured and estimated values of the solar PV cell output current. In this work, first, the values of RMSE calculated using 69 different methods published in many journal papers for the well-known RTC France solar PV cell are presented and discussed. Second, a novel exact analytical solution for RMSE calculation based on the Lambert W function is proposed. The results obtained show that the RMSE values were not calculated correctly in most of the methods presented in the literature since the exact expression of the calculated cell output current was not used. Third, the precision of calculation of the methods used for analytical solving of Lambert W equation is presented and discussed. Fourth, the applicability of the proposed solution methodology in accordance with current-voltage characteristics measured in the laboratory for solar modules of Clean Energy Trainer Setup is checked. Identification of its unknown parameters is presented using three optimization techniques. Further, the proposed solution methodology is proven for Solarex MSX–60 PV module, and the most promising 5-parameter single diode parameters are estimated based on minimization of the precise RMSE values calculated. Finally, this work aimed to develop a good base for proper investigation and implementation of optimization algorithms to solve the parameter estimation problem of 5-parameter single diode PV equivalent circuits.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.enconman.2020.112716

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 41 references

Metadata

Authors
Ćalasan, M., Abdel Aleem, S. H. E., & Zobaa, A. F.
Venue
Energy Conversion and Management
Publisher
Elsevier BV
Published
2020-04
Volume
210
Pages
112716
ISSN
0196-8904 (ISSN-L)
OpenAlex
W3012113472
Cited by
352
References
41
FWCI
7.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: On the root mean square error (RMSE) calculation for parameter estimation of photovoltaic models: A novel exact analytical solution based on Lambert W function. https://app.cochat.ai/papers/10.1016/j.enconman.2020.112716
The paper
Ćalasan, M., Abdel Aleem, S. H. E., & Zobaa, A. F. (2020). On the root mean square error (RMSE) calculation for parameter estimation of photovoltaic models: A novel exact analytical solution based on Lambert W function. Energy Conversion and Management. https://doi.org/10.1016/j.enconman.2020.112716

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.