Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 253

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Integrated supply–demand energy management for optimal design of off-grid hybrid renewable energy systems for residential electrification in arid climates

Open access
Mokhtara, Charafeddine, Negrou, Belkhir, Bouferrouk, Abdessalem, Yao, Yufeng, Settou, Noureddine, Ramadan, Mohamad·2020·Energy Conversion and Management

Abstract

Abstract The growing research interest in hybrid renewable energy systems (HRESs) has been regarded as a natural and yet critical response to address the challenge of rural electrification. Based on a Bibliometric analysis performed by authors, it was concluded that most studies simply adopted supply-side management techniques to perform the design optimization of such a renewable energy system. To further advance those studies, this paper presents a novel approach by integrating demand–supply management (DSM) with particle swarm optimization and applying it to optimally design an off-grid hybrid PV-solar-diesel-battery system for the electrification of residential buildings in arid environments, using a typical dwelling in Adrar, Algeria, as a case study. The proposed HRES is first modelled by an in-house MATLAB code based on a multi-agent system concept and then optimized by minimizing the total net present cost (TNPC), subject to reliability level and renewable energy penetration. After validation against the HOMER software, further techno-economic analyses including sensitivity study are undertaken, considering different battery technologies. By integrating the proposed DSM, the results have shown the following improvements: with RF = 100%, the energy demand and TNPC are reduced by 7% and 18%, respectively, compared to the case of using solely supply-side management. It is found that PV-Li-ion represents the best configuration, with TNPC of $23,427 and cost of energy (COE) of 0.23 $/kWh. However, with lower RF values, the following reductions are achieved: energy consumption (19%) and fuel consumption or CO2 emission (57%), respectively. In contrast, the RF is raised from 15% (without DSM) to 63% (with DSM). It is clear that the optimal configuration consists of wind-diesel, with COE of 0.21 $/kWh, smaller than that obtained with a stand-alone diesel generator system. The outcomes of this work can provide valuable insights into the successful design and deployment of HRES in Algeria and surrounding regions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.enconman.2020.113192

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Cited by

See all 253

Metadata

Authors
Mokhtara, C., Negrou, B., Bouferrouk, A., Yao, Y., Settou, N., & Ramadan, M.
Venue
Energy Conversion and Management
Publisher
Elsevier BV
Published
2020-10
Volume
221
Pages
113192
ISSN
0196-8904 (ISSN-L)
OpenAlex
W3042583737
Cited by
253
References
27
FWCI
10.76
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Integrated supply–demand energy management for optimal design of off-grid hybrid renewable energy systems for residential electrification in arid climates. https://app.cochat.ai/papers/10.1016/j.enconman.2020.113192
The paper
Mokhtara, C., Negrou, B., Bouferrouk, A., Yao, Y., Settou, N., & Ramadan, M. (2020). Integrated supply–demand energy management for optimal design of off-grid hybrid renewable energy systems for residential electrification in arid climates. Energy Conversion and Management. https://doi.org/10.1016/j.enconman.2020.113192

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.