Microgrid energy management strategies assessment through coupled thermal-electric considerations
Abstract
Abstract Battery Energy Storage Systems (BESSs) are considered as one of the most promising technological options towards high self-sufficiency of building facilities and higher independency from the main grid through autonomous operation. At the same time, BESS are an essential component for a cost-optimized operation of grid-connected microgrids. In addition, the ever-increasing trend to replace conventional heating systems with electrically driven heat pumps, reveals a continuously emerging trend for electrification supported by electrical storage systems. In this study, a grid-connected microgrid of a sport centre facility located in Barcelona (Spain), which includes i) a solar PV (Photovoltaic) installation, ii) a BESS and iii) a heat pump (HP), is investigated through dynamic simulations, considering both thermal and electrical loads. Targeting the best compromise between self-sufficiency and reduction in the cost of electricity, two different energy management strategies are examined for the supervision and control of the grid-connected microgrid operation, taking into account the impact of the already operating HVAC (Heating Ventilation and Air Conditioning) systems along with the HP operation. In particular, the investigated energy management strategies are considered to be two of the most prominent ones and involve 1) peak shaving of the microgrid consumption with off-peak grid power and 2) pricing-based operation of the BESS (arbitrage), according to the main grid electricity price. Under this scope, an integrated thermal and electrical dynamic model of the sport centre energy system is developed in APROS software. The results are benchmarked against the corresponding ones from the standard model of TRNSYS. The impact of each management strategy is assessed in terms of the resulting power flows and the associated cost of electricity, for each operational mode. Based on the simulation results, the most advantageous energy management algorithm is determined for each case study, revealing that the integrated thermal-electrical dynamic modelling can be a useful tool for designing adaptive energy management algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
Cited by 31
Research works printed but not linked: 31
- E. Trianti-Stourna, K. Spyropoulou, C. Theofylaktos, K. Droutsa, C.A. Balaras, M. Santamouris, et al. Energy conservation strategies for sports centers: Part A. Sports halls. Energy and Buildings. 27 (1998) 109-22. · doi:10.1016/s0378-7788(97)00040-6
- I. Sarbu, C. Sebarchievici. Performance Evaluation of Radiator and Radiant Floor Heating Systems for an Office Room Connected to a Ground-Coupled Heat Pump2016. · doi:10.3390/en9040228
- Januševičius, 2016, Validation of unglazed transpired solar collector assisted air source heat pump simulation model, Energy Procedia, 95, 167, 10.1016/j.egypro.2016.09.039 · DOI
- Grossi, 2018, Dynamic modelling and energy performance analysis of an innovative dual-source heat pump system, Appl Therm Eng, 142, 745, 10.1016/j.applthermaleng.2018.07.022 · doi:10.1016/j.applthermaleng.2018.07.022
- Fu, 2003, Dynamic simulation of air-to-water dual-mode heat pump with screw compressor, Appl Therm Eng, 23, 1629, 10.1016/S1359-4311(03)00109-1 · doi:10.1016/s1359-4311(03)00109-1
- Jin, 2017, Annual energy performance of R744 and R410A heat pumping systems, Appl Therm Eng, 117, 568, 10.1016/j.applthermaleng.2017.02.072 · doi:10.1016/j.applthermaleng.2017.02.072
- Dong, 2015, Self-optimizing control of air-source heat pump with multivariable extremum seeking, Appl Therm Eng, 84, 180, 10.1016/j.applthermaleng.2015.03.038 · DOI
- Park, 2014, Heat pump control method based on direct measurement of evaporation pressure to improve energy efficiency and indoor air temperature stability at a low cooling load condition, Appl Energy, 132, 99, 10.1016/j.apenergy.2014.07.011 · doi:10.1016/j.apenergy.2014.07.011
- Liu, 2018, Model-based dynamic optimal control of a CO2 heat pump coupled with hot and cold thermal storages, Appl Therm Eng, 128, 1116, 10.1016/j.applthermaleng.2017.09.098 · doi:10.1016/j.applthermaleng.2017.09.098
- Lee, 2018, Simulation-based optimization of heating and cooling seasonal performances of an air-to-air heat pump considering operating and design parameters using genetic algorithm, Appl Therm Eng, 144, 362, 10.1016/j.applthermaleng.2018.08.078 · DOI
- Madani, 2011, Capacity control in ground source heat pump systems: Part I: modeling and simulation, Int J Refrig, 34, 1338, 10.1016/j.ijrefrig.2011.05.007 · doi:10.1016/j.ijrefrig.2011.05.007
- Ekren, 2010, Comparison of different controllers for variable speed compressor and electronic expansion valve, Int J Refrig, 33, 1161, 10.1016/j.ijrefrig.2010.05.005 · doi:10.1016/j.ijrefrig.2010.05.005
- Goyal, 2019, A review of control methodologies for vapor compression and absorption heat pumps, Int J Refrig, 97, 1, 10.1016/j.ijrefrig.2018.08.026 · doi:10.1016/j.ijrefrig.2018.08.026
- Marcinichen, 2008, A dual siso controller for a vapor compression refrigeration, System
- Yang, 2016, Energy regulating and fluctuation stabilizing by air source heat pump and battery energy storage system in microgrid, Renewable Energy, 95, 202, 10.1016/j.renene.2016.04.019 · DOI
- Kim, 2015, Modeling and analysis of a variable speed heat pump for frequency regulation through direct load control, IEEE Trans Power Syst, 30, 397, 10.1109/TPWRS.2014.2319310 · DOI · Paper page
- Stanek, 2019, Exergetic and thermo-ecological assessment of heat pump supported by electricity from renewable sources, Renewable Energy, 131, 404, 10.1016/j.renene.2018.07.084 · doi:10.1016/j.renene.2018.07.084
- Li, 2016, Dynamic performance of the standalone wind power driven heat pump, Energy Procedia, 103, 40, 10.1016/j.egypro.2016.11.246 · doi:10.1016/j.egypro.2016.11.246
- Schibuola, 2015, Demand response management by means of heat pumps controlled via real time pricing, Energy Build, 90, 15, 10.1016/j.enbuild.2014.12.047 · DOI
- Meesenburg, 2018, Dynamic exergoeconomic analysis of a heat pump system used for ancillary services in an integrated energy system, Energy, 152, 154, 10.1016/j.energy.2018.03.093 · DOI
- Linssen, 2017, Techno-economic analysis of photovoltaic battery systems and the influence of different consumer load profiles, Appl Energy, 185, 2019, 10.1016/j.apenergy.2015.11.088 · DOI
- Sani Hassan, 2017, Optimal battery storage operation for PV systems with tariff incentives, Appl Energy, 203, 422, 10.1016/j.apenergy.2017.06.043 · DOI · Paper page
- García-Plaza, 2018, Peak shaving algorithm with dynamic minimum voltage tracking for battery storage systems in microgrid applications, J Storage Mater, 20, 41
- Solano, 2017, Assessing the potential of PV hybrid systems to cover HVAC loads in a grid-connected residential building through intelligent control, Appl Energy, 206, 249, 10.1016/j.apenergy.2017.08.188 · doi:10.1016/j.apenergy.2017.08.188
- Buonomano, 2018, A hybrid renewable system based on wind and solar energy coupled with an electrical storage: Dynamic simulation and economic assessment, Energy., 155, 174, 10.1016/j.energy.2018.05.006 · DOI
- Karlsson, 2007, Capacity Control for residential Heat Pump, Heating Systems.
- Lemmon, 2018, Standard Reference Database 23: Reference Fluid Thermodynamic and Transport Properties-REFPROP. National Institute of Standards and Technology, Standard Reference Data Program, Gaithersburg
- Santa, 2012, The analysis of two-phase condensation heat transfer models based on the comparison of the boundary, Condition
- W. Zhou, H. Yang, Z. Fang. A novel model for photovoltaic array performance prediction2007. · doi:10.1016/j.apenergy.2007.04.006
- Chapaloglou, 2019, Smart energy management algorithm for load smoothing and peak shaving based on load forecasting of an island’s power system, Appl Energy, 238, 627, 10.1016/j.apenergy.2019.01.102 · DOI · Paper page
- D. Ciupageanu, L. Barelli, A. Ottaviano, D. Pelosi, G. Lazaroiu. Innovative power management of hybrid energy storage systems coupled to RES plants: The Simultaneous Perturbation Stochastic Approximation approach. 2019 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)2019. pp. 1-5. · DOI
Metadata
- Authors
- Chapaloglou, S., Nesiadis, A., Atsonios, K., Nikolopoulos, N., Grammelis, P., Carrera, A., & Camara, O.
- Venue
- Energy Conversion and Management
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 228
- Pages
- 113711
- ISSN
- 0196-8904
- Cited by
- 31
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Funders
- Innovation and Networks Executive Agency
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microgrid energy management strategies assessment through coupled thermal-electric considerations. https://app.cochat.ai/papers/10.1016/j.enconman.2020.113711
- The paper
- Chapaloglou, S., Nesiadis, A., Atsonios, K., Nikolopoulos, N., Grammelis, P., Carrera, A., & Camara, O. (2021). Microgrid energy management strategies assessment through coupled thermal-electric considerations. Energy Conversion and Management. https://doi.org/10.1016/j.enconman.2020.113711
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.