The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
An MILP approach for the optimal design of renewable battery-hydrogen energy systems for off-grid insular communities
Open accessAbstract
The optimal sizing of stand-alone renewable H2-based microgrids requires the load demand to be reliably satisfied by means of local renewable energy supported by a hybrid battery/hydrogen storage unit, while minimizing the system costs. However, this task is challenging because of the high number of components that have to be installed and operated. In this work, an MILP optimization framework has been developed and applied to the off-grid village of Ginostra (on the Stromboli island, Italy), which is a good example of several other insular sites throughout the Mediterranean area. A year-long time horizon was considered to model the seasonal storage, which is necessary for off-grid areas that wish to achieve energy independence by relying on local renewable sources. The degradation costs of batteries and H2-based devices were included in the objective function of the optimization problem, i.e., the annual cost of the system. Efficiency and investment cost curves were considered for the electrolyzer and fuel cell components in order to obtain a more detailed and precise techno-economic estimation. The design optimization was also performed with the inclusion of a general demand response program (DRP) to assess its impact on the sizing results. Moreover, the effectiveness of the proposed MILP-based method was tested by comparing it with a more traditional approach, based on a metaheuristic algorithm for the optimal sizing complemented with ruled-based strategies for the system operation. Thanks to its longer-term storage capability, hydrogen is required for the optimal system configuration in order to reach energy self-sufficiency. Finally, considering the possibility of load deferral, the electricity generation cost can be reduced to an extent that depends on the amount of load that is allowed to participate in the DRP scheme. This cost reduction is mainly due to the decreased capacity of the battery storage system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Luo, X., Wang, J., Dooner, M., & Clarke, J. (2015) · Applied Energy · doi:10.1016/j.apenergy.2014.09.081 · Cited by 3,869
Cited by
Terlouw, T., Bauer, C., McKenna, R., & Mazzotti, M. (2022) · Energy & Environmental Science · doi:10.1039/d2ee01023b · Cited by 680
Power-to-X: A review and perspective.
Palys, M. J., & Daoutidis, P. (2022) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2022.107948 · Cited by 190
Metadata
- Authors
- Marocco, P., Ferrero, D., Martelli, E., Santarelli, M., & Lanzini, A.
- Venue
- Energy Conversion and Management
- Publisher
- Elsevier BV
- Published
- 2021-10
- Volume
- 245
- Pages
- 114564
- ISSN
- 0196-8904 (ISSN-L)
- OpenAlex
- W3192953634
- Cited by
- 175
- References
- 1
- FWCI
- 6.27
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An MILP approach for the optimal design of renewable battery-hydrogen energy systems for off-grid insular communities. https://app.cochat.ai/papers/10.1016/j.enconman.2021.114564
- The paper
- Marocco, P., Ferrero, D., Martelli, E., Santarelli, M., & Lanzini, A. (2021). An MILP approach for the optimal design of renewable battery-hydrogen energy systems for off-grid insular communities. Energy Conversion and Management. https://doi.org/10.1016/j.enconman.2021.114564
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.