The DOI matches its Crossref record.
Passive options for solar cooling of buildings in arid areas
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In this regard, by analyzing the hourly average values of beam and diffuse radiation for a typical summer day, Amer [15] found that a horizontal roof receives around 1.5 times more solar radiation than a west-facing wall and about four times more than a south-facing wall.”
From The Potential of Using Passive Cooling Roof Techniques to Improve Thermal Performance and Energy Efficiency of Residential Buildings in Hot Arid Regions (2022) · cites this paper as Amer [15]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 14
- Duffin, 1984, A passive wall design to minimize building temperature swings, Sol Energy, 33, 337, 10.1016/0038-092X(84)90163-4 · DOI
- Hay, 1969, International aspects of air conditioning with movable insulation, Sol Energy, 12, 427, 10.1016/0038-092X(69)90065-6 · DOI
- Niles, 1976, Thermal evaluation of a house using a movable insulation heating and cooling, Sol Energy, 18, 413, 10.1016/0038-092X(76)90007-4 · DOI
- Ohanessian, 1978, Thermal insulation of a passive solar house using a Trombe Michel wall, Sol Energy, 20, 275, 10.1016/0038-092X(78)90106-8 · DOI
- Robbins, 1980, Computer modeling of ventilated Trombe wall with actual performance data, Sol Energy, 25, 207, 10.1016/0038-092X(80)90325-4 · DOI
- Bilgen, 1982, Solar heating–ventilating system using a solar chimney, Sol Energy, 28, 227, 10.1016/0038-092X(82)90161-X · DOI
- Yadav, 1983, Digital simulation of indoor temperatures of buildings with roof ponds, Sol Energy, 31, 205, 10.1016/0038-092X(83)90083-X · DOI
- Sodha, 1978, Reduction of heat flux through a roof by water film, Sol Energy, 20, 189, 10.1016/0038-092X(78)90196-2 · DOI
- Chandra, 1983, Temperature control in building with evaporated cooling and variable ventilation, Sol Energy, 30, 381, 10.1016/0038-092X(83)90193-7 · DOI
- Givoni, 1991, Characteristics, design implications and applicability of passive solar systems, Sol Energy, 47, 425, 10.1016/0038-092X(91)90110-I · DOI
- Onmura, 2001, Study on evaporative cooling effect of roof lawn gardens, Energy and Buildings, 33, 653, 10.1016/S0378-7788(00)00134-1 · DOI
- Jiang, 2001, A solar cooling project for hot and humid climates, Sol Energy, 70, 135
- Raman, 2001, A passive solar system for thermal comfort conditioning of buildings in composite climates, Sol Energy, 70, 319, 10.1016/S0038-092X(00)00147-X · DOI
- Florides, 2002, Measures used to lower building energy consumption and their cost effectiveness, Appl Energy, 73, 299, 10.1016/S0306-2619(02)00119-8 · DOI
Cited by
Sorted by citations
Thermal performance of reflective materials applied to exterior building components—A review
Hernández-Pérez, I., Álvarez, G., Xamán, J., Zavala-Guillén, I., Arce, J., & Simá, E. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.05.008 · Cited by 167
Abuseif, M., & Gou, Z. (2018) · Energies · doi:10.3390/en11113196 · Cited by 66
Athmani, W., Sriti, L., Dabaieh, M., & Younsi, Z. (2022) · Buildings · doi:10.3390/buildings13010021 · Cited by 49
Metadata
- Authors
- Amer, E. H.
- Affiliations
- Menoufia University (EG)
- Corresponding author
- Amer, Emad H.
- ORCID
- Amer, Emad H.
- Venue
- Energy
- Publisher
- Elsevier BV
- Published
- 2006-07
- Volume
- 31
- Issue
- 8-9
- Pages
- 1332-1344
- ISSN
- 0360-5442 (ISSN-L)
- OpenAlex
- W2019889385
- Cited by
- 72
- References
- 0
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 9 · 2023: 2 · 2022: 2 · 2021: 8 · 2020: 7 · 2019: 4 · 2018: 9 · 2017: 3 · 2016: 2 · 2015: 1 · 2014: 3 · 2013: 1 · 2012: 5
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Energy (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Physical Sciences › Engineering › Building and Construction › Solar Energy Systems and Technologies
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- passive solar cooling, building thermal load, arid climate, indoor temperature, thermal insulation, evaporative cooling, solar chimney, metal structures, workshops
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review