High temperature heat pumps: Market overview, state of the art, research status, refrigerants, and application potentials
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
This study reviews the current state of the art and the current research activities of high temperature heat pumps (HTHPs) with heat sink temperatures in the range of 90 to 160 °C. The focus is on the analysis of the heat pump cycles and the suitable refrigerants. More than 20 HTHPs from 13 manufacturers have been identified on the market that are able to provide heat sink temperatures of at least 90 °C. Large application potentials have been recognized particularly in the food, paper, metal and chemical industries. The heating capacities range from about 20 kW to 20 MW. Most cycles are single-stage and differ primarily in the refrigerant (e.g. R245fa, R717, R744, R134a or R1234ze(E)) and compressor type used. The COPs range from 2.4 to 5.8 at a temperature lift of 95 to 40 K. Several research projects push the limits of the achievable COPs and heat sink temperatures to higher levels. COPs of about 5.7 to 6.5 (at 30 K lift) and 2.2 and 2.8 (70 K) are achieved at a sink temperature of 120 °C. The refrigerants investigated are mainly R1336mzz(Z), R718, R245fa, R1234ze(Z), R600, and R601. R1336mzz(Z) enables to achieve exceptionally high heat sink temperatures of up to 160 °C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kyoto Protocol to the United Nations Framework Convention on Climate Change
(2018) · International Law Documents · doi:10.1017/9781316577226.067 · Cited by 4,351
Anthropogenic and Natural Radiative Forcing
(2014) · Climate Change 2013 – The Physical Science Basis · doi:10.1017/cbo9781107415324.018 · Cited by 3,683
Kyoto Protocol to the United Nations Framework Convention on Climate Change
(1998) · Review of European Community & International Environmental Law · doi:10.1111/1467-9388.00150 · Cited by 865
The potential of solar industrial process heat applications
Kalogirou, S. A. (2003) · Applied Energy · doi:10.1016/s0306-2619(02)00176-9 · Cited by 633
Zhang, J., Zhang, H.-H., He, Y.-L., & Tao, W.-Q. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.06.049 · Cited by 242
Brunin, O., Feidt, M. L., & Hivet, B. (1997) · International Journal of Refrigeration · doi:10.1016/s0140-7007(97)00025-x · Cited by 227
Review of vapour compression heat pumps for high temperature heating using natural working fluids
Bamigbetan, O., Eikevik, T. M., Nekså, P., & Bantle, M. (2017) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.04.021 · Cited by 191
Quantification of the European industrial heat demand by branch and temperature level
Naegler, T., Simon, S., Klein, M., & Gils, H. C. (2015) · International Journal of Energy Research · doi:10.1002/er.3436 · Cited by 166
A bottom-up estimation of the heating and cooling demand in European industry
Rehfeldt, M., Fleiter, T., & Toro, F. (2017) · Energy Efficiency · doi:10.1007/s12053-017-9571-y · Cited by 156
Molés, F., Navarro-Esbrí, J., Peris, B., Mota-Babiloni, A., Barragán-Cervera, Á., & Kontomaris, K. K. (2014) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2014.06.055 · Cited by 142
Cited by
Degen, F., Winter, M., Bendig, D., & Tübke, J. (2023) · Nature Energy · doi:10.1038/s41560-023-01355-z · Cited by 861
“…required to produce a single LIB and a single PLIB cell with 1 kWh cell of cell energy, in addition to the battery cell type, four techno-economic effects were addressed: technology improvements 29,35,40–43 , use of heat pumps 31,44 , learning effects 35,43,45 and economies of scale 43,46,47 .”
BackgroundPotential and risks of hydrogen-based e-fuels in climate change mitigation
Ueckerdt, F., Bauer, C., Dirnaichner, A., Everall, J., Sacchi, R., & Luderer, G. (2021) · Nature Climate Change · doi:10.1038/s41558-021-01032-7 · Cited by 709
McQueen, N., Gomes, K. V., McCormick, C., Blumanthal, K., Pisciotta, M., & Wilcox, J. (2021) · Progress in Energy · doi:10.1088/2516-1083/abf1ce · Cited by 702
Heat pumps and our low-carbon future: A comprehensive review
Gaur, A. S., Fitiwi, D. Z., & Curtis, J. (2021) · Energy Research & Social Science · doi:10.1016/j.erss.2020.101764 · Cited by 533
To decarbonize industry, we must decarbonize heat
Thiel, G. P., & Stark, A. K. (2021) · Joule · doi:10.1016/j.joule.2020.12.007 · Cited by 339
Madeddu, S., Ueckerdt, F., Pehl, M., Peterseim, J., Lord, M., Kumar, K. A., Krüger, C., & Luderer, G. (2020) · Environmental Research Letters · doi:10.1088/1748-9326/abbd02 · Cited by 295
Life Cycle Assessment of Direct Air Carbon Capture and Storage with Low-Carbon Energy Sources
Terlouw, T., Treyer, K., Bauer, C., & Mazzotti, M. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.1c03263 · Cited by 294
Vapor compression heat pumps with pure Low-GWP refrigerants
Wu, D., Hu, B., & Wang, R. Z. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110571 · Cited by 283
Schoeneberger, C. A., McMillan, C. A., Kurup, P., Akar, S., Margolis, R., & Masanet, E. (2020) · Energy · doi:10.1016/j.energy.2020.118083 · Cited by 177
Rehfeldt, M., Worrell, E., Eichhammer, W., & Fleiter, T. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.109672 · Cited by 161
Juhola, V., Mikkola, V., Inkeri, E., Kabelac, S., & Tynjälä, T. (2025) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2025.127396 · Cited by 9
Metadata
- Authors
- Arpagaus, C., Bless, F., Uhlmann, M., Schiffmann, J., & Bertsch, S. S.
- Venue
- Energy
- Publisher
- Elsevier BV
- Published
- 2018-06
- Volume
- 152
- Pages
- 985-1010
- ISSN
- 0360-5442 (ISSN-L)
- OpenAlex
- W2794947837
- Cited by
- 841
- References
- 15
- FWCI
- 28.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.