Impact of climate change on heating and cooling energy demand in a residential building in a Mediterranean climate
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A range of energy improvement measures applied to a typical Mediterranean residential building are modelled under various climate-change scenarios. Global Circulation Models (CNRM-CM5 and MPI-ESM-LR), under two emission scenarios (RCP4.5 and RCP8.5), downscaled by the Spanish Meteorological Agency, are used to generate four temperature projections. Energy simulations are obtained with TRNSYS tools in a Mediterranean climate based on temperature projections in two periods: 2048–2052 and 2096–2100, with the same time span. Various energy measures apply thermal improvements to a conventional residential building model that complies with current regulations for this analysis of best practice in passive construction solutions. Sequential implementation of eight different energy improvements measures are applied to the initial building model: six passives (infiltration, insulation thickness, glazing and frame type, window area, shading devices and natural cross ventilation) and two active (mechanical ventilation and a heat recovery system) measures. The climatic trends that are predicted show a local scenario with a warming climate and the thermal behaviour of the building is shown to differ in each scenario. The demand for indoor heating decreases significantly when the outdoor temperature increases, while the demand for cooling and the risk of overheating increase considerably in all the scenarios. The data for the building conditions that are projected in this study predict that natural and forced ventilation strategies will have the least impact, while increased thermal insulation and reductions in infiltration will have a greater effect on global energy demand.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
World map of the Köppen-Geiger climate classification updated
Kottek, M., Grieser, J., Beck, C., Rudolf, B., & Rubel, F. (2006) · Meteorologische Zeitschrift · doi:10.1127/0941-2948/2006/0130 · Cited by 11,456
The next generation of scenarios for climate change research and assessment
Moss, R. H., Edmonds, J. A., Hibbard, K. A., Manning, M. R., Rose, S. K., van Vuuren, D. P., Carter, T. R., Emori, S., Kainuma, M., Kram, T., et al. (2010) · Nature · doi:10.1038/nature08823 · Cited by 6,467
Impact of climate change heating and cooling energy use in buildings in the United States
Wang, H., & Chen, Q. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.07.034 · Cited by 364
Cited by
Rahif, R., Kazemi, M., & Attia, S. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.112998 · Cited by 51
Beyond energy savings: Investigating the co-benefits of heat resilient architecture
Samuelson, H. W., Baniassadi, A., & Gonzalez, P. I. (2020) · Energy · doi:10.1016/j.energy.2020.117886 · Cited by 39
Metadata
- Authors
- Pérez-Andreu, V., Aparicio-Fernández, C., Martínez-Ibernón, A., & Vivancos, J.-L.
- Venue
- Energy
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 165
- Pages
- 63-74
- ISSN
- 0360-5442 (ISSN-L)
- OpenAlex
- W2890675889
- Cited by
- 164
- References
- 3
- FWCI
- 10.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.