Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 199

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Thermal performance evaluation of non-uniform fin array in a finned double-pipe latent heat storage system

Shahsavar, Amin, Goodarzi, Abbas, Mohammed, Hayder I., Shirneshan, Alireza, Talebizadehsardari, Pouyan · 2020 · Energy

Abstract

This paper aims to evaluate the effects of fin arrangement in a vertical finned double-pipe latent heat storage system based on the locations, thickness and diameter of the fins in melting and solidification mechanisms. The PCM is placed in the outer tube while water is passed through the inner tube. The fins are circularly placed around the inner pipe in the PCM zone considering a constant fins number. The results show significant advantages of fins addition in reducing the melting time along with a lower advantage on the solidification time. For the uniform fin array compared with the non-fined case, the melting and solidification times reduces by 41.4% and 9.7%, respectively. For the best fin array compared with the uniform case, the melting time reduces by 23.9%. For the solidification process, the best case is the uniform distribution of the fins when the rate of heat recovery increases by 11.4% compared with the non-finned case. Furthermore, the melting time reduces by decreasing the thickness of the fins. The evaluation of fins’ diameter shows that after a certain diameter, increasing the diameter of the fins shows an adverse effect due to suppressing the natural convection effect.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.energy.2019.116800

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 199

Metadata

Authors
Shahsavar, A., Goodarzi, A., Mohammed, H. I., Shirneshan, A., & Talebizadehsardari, P.
Venue
Energy
Publisher
Elsevier BV
Published
2020-02
Volume
193
Pages
116800
ISSN
0360-5442 (ISSN-L)
OpenAlex
W2998013564
Cited by
199
References
6
FWCI
12.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Thermal performance evaluation of non-uniform fin array in a finned double-pipe latent heat storage system. https://app.cochat.ai/papers/10.1016/j.energy.2019.116800
The paper
Shahsavar, A., Goodarzi, A., Mohammed, H. I., Shirneshan, A., & Talebizadehsardari, P. (2020). Thermal performance evaluation of non-uniform fin array in a finned double-pipe latent heat storage system. Energy. https://doi.org/10.1016/j.energy.2019.116800

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.