The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Strength, stiffness and ductility of concrete-filled steel columns under axial compression
Open accessAbstract
Abstract Extensive experimental and theoretical studies have been conducted on the compressive strength of concrete-filled steel tubular (CFST) columns, but little attention has been paid to their compressive stiffness and deformation capacity. Despite this, strength prediction approaches in existing design codes still have various limitations. A finite element model, which was previously proposed by the authors and verified using a large amount of experimental data, is used in this paper to generate simulation data covering a wide range of parameters for circular and rectangular CFST stub columns under axial compression. Regression analysis is conducted to propose simplified models to predict the compressive strength, the compressive stiffness, and the compressive strain corresponding to the compressive strength (ductility) for the composite columns. Based on the new strength prediction model, the capacity reduction factors for the steel and concrete materials are recalibrated to achieve a target reliability index of 3.04 when considering resistance effect only.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neville, A. M. (1968) · Virtual Defense Library (Ministerio de Defensa) · Cited by 5,444
International Organization for Standardization (ISO)
Nahler, G. (2009) · Dictionary of Pharmaceutical Medicine · doi:10.1007/978-3-211-89836-9_723 · Cited by 3,677
Developments and advanced applications of concrete-filled steel tubular (CFST) structures: Members
Han, L.-H., Li, W., & Bjorhovde, R. (2014) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2014.04.016 · Cited by 1,830
Self-citationFinite element modelling of concrete-filled steel stub columns under axial compression
Tao, Z., Wang, Z.-B., & Yu, Q. (2013) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2013.07.001 · Cited by 1,297
Self-citationEuropean Committee for Standardization (CEN)
(2022) · The Fairchild Books Dictionary of Fashion · doi:10.5040/9781501365287.967 · Cited by 1,286
Chung, K. F., & Narayanan, R. G. (1994) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 1,132
Design-Oriented Stress-Strain Model for FRP-Confined Concrete in Rectangular Columns
Lam, L., & Teng, J. G. (2003) · Journal of Reinforced Plastics and Composites · doi:10.1177/0731684403035429 · Cited by 692
Axial capacity of circular concrete-filled tube columns
Giakoumelis, G., & Lam, D. (2004) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2003.10.001 · Cited by 638
Self-citationHan, L.-H., Yao, G.-H., & Zhao, X.-L. (2005) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2005.01.004 · Cited by 616
Self-citationState of the art report on steel–concrete composite columns
Shanmugam, N. E., & Lakshmi, B. (2001) · Journal of Constructional Steel Research · doi:10.1016/s0143-974x(01)00021-9 · Cited by 466
Behaviour of short and slender concrete-filled stainless steel tubular columns
Uy, B., Tao, Z., & Han, L.-H. (2011) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2010.10.004 · Cited by 462
Self-citationTests on stub columns of concrete-filled RHS sections
Han, L. (2002) · Journal of Constructional Steel Research · doi:10.1016/s0143-974x(01)00059-1 · Cited by 448
Self-citationStress-Strain Curves of Structural and Reinforcing Steels after Exposure to Elevated Temperatures
Tao, Z., Wang, X.-Q., & Uy, B. (2013) · Journal of Materials in Civil Engineering · doi:10.1061/(asce)mt.1943-5533.0000676 · Cited by 425
Self-citationBond behavior in concrete-filled steel tubes
Tao, Z., Song, T.-Y., Uy, B., & Han, L.-H. (2016) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2015.12.030 · Cited by 296
Self-citationMechanical Behavior of Circular Steel–Concrete Composite Stub Columns
Johansson, M., & Gylltoft, K. (2002) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(2002)128:8(1073 · Cited by 165
Huo, J., Huang, G., & Xiao, Y. (2009) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2009.04.022 · Cited by 125
Ultimate capacity prediction of axially loaded CFST short columns
Güneyisi, E. M., Gültekin, A., & Mermerdaş, K. (2016) · International Journal of Steel Structures · doi:10.1007/s13296-016-3009-9 · Cited by 86
Suggested empirical models for the axial capacity of circular CFT stub columns
Lu, Z., & Zhao, Y. (2010) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2009.12.014 · Cited by 75
Predicting the axial load capacity of high-strength concrete filled steel tubular columns
Aslani, F., Uy, B., Tao, Z., & MASHIRI, F. R. (2015) · Steel and Composite Structures · doi:10.12989/scs.2015.19.4.967 · Cited by 50
Self-citation
Cited by
Lyu, F., Fan, X., Ding, F., & Chen, Z. (2021) · Composite Structures · doi:10.1016/j.compstruct.2021.114282 · Cited by 77
Huang, W., Fan, Z., Shen, P., Lu, L., & Zhou, Z. (2020) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2020.119150 · Cited by 69
Metadata
- Authors
- Wang, Z.-B., Tao, Z., Han, L.-H., Uy, B., Lam, D., & Kang, W.-H.
- Venue
- Engineering Structures
- Publisher
- Elsevier BV
- Published
- 2017-03
- Volume
- 135
- Pages
- 209-221
- ISSN
- 0141-0296 (ISSN-L)
- OpenAlex
- W2577081734
- Cited by
- 324
- References
- 19
- FWCI
- 20.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.