The DOI matches its Crossref record.
Pumped storage in systems with very high wind penetration
Open accessAbstract
This paper examines the operation of the Irish power system with very high levels of wind energy, with and without pumped storage. A unit commitment model which accounts for the uncertainty in wind power is used. It is shown that as wind penetration increases, the optimal operation of storage depends on wind output as well as load. The main benefit from storage is shown to be a decrease in wind curtailment. The economics of the system are examined to find the level at which storage justifies its capital costs and inefficiencies. It is shown that the uncertainty of wind makes the option of storage more attractive. The size of the energy store has an impact on results. At lower levels of installed wind (up to approximately 50% of energy from wind in Ireland), the reduction in curtailment is insufficient to justify building storage. At greater levels of wind, storage reduces curtailment sufficiently to justify the additional capital costs. It can be seen that if storage replaces OCGTs in the plant mix instead of CCGTs, then the level at which it justifies itself is lower. Storage increases the level of carbon emissions at wind penetration below 60%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pumped hydro energy storage system: a technological review
Rehman, S., Al-Hadhrami, L. M., & Alam, M. M. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.12.040 · Cited by 1,264
The market value of variable renewables
Hirth, L. (2013) · Energy Economics · doi:10.1016/j.eneco.2013.02.004 · Cited by 923
Solar and wind power generation systems with pumped hydro storage: Review and future perspectives
Javed, M. S., Ma, T., Jurasz, J., & Amin, M. Y. (2020) · Renewable Energy · doi:10.1016/j.renene.2019.11.157 · Cited by 482
The value of energy storage in decarbonizing the electricity sector
de Sisternes, F. J., Jenkins, J. D., & Botterud, A. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.05.014 · Cited by 446
A review of mechanical energy storage systems combined with wind and solar applications
Mahmoud, M., Ramadan, M., Olabi, A.-G., Pullen, K., & Naher, S. (2020) · Energy Conversion and Management · doi:10.1016/j.enconman.2020.112670 · Cited by 430
Ma, T., Yang, H., Lu, L., & Peng, J. (2014) · Renewable Energy · doi:10.1016/j.renene.2014.03.028 · Cited by 407
Trends and challenges in the operation of pumped-storage hydropower plants
Pérez-Díaz, J. I., Chazarra, M., García-González, J., Cavazzini, G., & Stoppato, A. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.01.029 · Cited by 328
The Market Value of Variable Renewables
Hirth, L., & Hirth, L. (2012) · AgEcon Search (University of Minnesota, USA) · doi:10.22004/ag.econ.122021 · Cited by 325
A systematic review of the costs and impacts of integrating variable renewables into power grids
Heptonstall, P. J., & Gross, R. J. K. (2020) · Nature Energy · doi:10.1038/s41560-020-00695-4 · Cited by 321
Integration of Renewable Energy into Present and Future Energy Systems
Sims, R., Mercado, P., Krewitt, W., Bhuyan, G., Flynn, D., Holttinen, H., Jannuzzi, G., Khennas, S., Liu, Y., Nilsson, L. J., et al. (2011) · Renewable Energy Sources and Climate Change Mitigation · doi:10.1017/cbo9781139151153.012 · Cited by 98
Self-citation
Metadata
- Authors
- Tuohy, A., & O’Malley, M.
- Venue
- Energy Policy
- Publisher
- Elsevier BV
- Published
- 2011-04
- Volume
- 39
- Issue
- 4
- Pages
- 1965-1974
- ISSN
- 0301-4215 (ISSN-L)
- OpenAlex
- W2063966652
- Cited by
- 218
- References
- 0
- FWCI
- 14.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.