The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Applications of low-cost sensing technologies for air quality monitoring and exposure assessment: How far have they gone?
Open accessAbstract
Over the past decade, a range of sensor technologies became available on the market, enabling a revolutionary shift in air pollution monitoring and assessment. With their cost of up to three orders of magnitude lower than standard/reference instruments, many avenues for applications have opened up. In particular, broader participation in air quality discussion and utilisation of information on air pollution by communities has become possible. However, many questions have been also asked about the actual benefits of these technologies. To address this issue, we conducted a comprehensive literature search including both the scientific and grey literature. We focused upon two questions: (1) Are these technologies fit for the various purposes envisaged? and (2) How far have these technologies and their applications progressed to provide answers and solutions? Regarding the former, we concluded that there is no clear answer to the question, due to a lack of: sensor/monitor manufacturers' quantitative specifications of performance, consensus regarding recommended end-use and associated minimal performance targets of these technologies, and the ability of the prospective users to formulate the requirements for their applications, or conditions of the intended use. Numerous studies have assessed and reported sensor/monitor performance under a range of specific conditions, and in many cases the performance was concluded to be satisfactory. The specific use cases for sensors/monitors included outdoor in a stationary mode, outdoor in a mobile mode, indoor environments and personal monitoring. Under certain conditions of application, project goals, and monitoring environments, some sensors/monitors were fit for a specific purpose. Based on analysis of 17 large projects, which reached applied outcome stage, and typically conducted by consortia of organizations, we observed that a sizable fraction of them (~ 30%) were commercial and/or crowd-funded. This fact by itself signals a paradigm change in air quality monitoring, which previously had been primarily implemented by government organizations. An additional paradigm-shift indicator is the growing use of machine learning or other advanced data processing approaches to improve sensor/monitor agreement with reference monitors. There is still some way to go in enhancing application of the technologies for source apportionment, which is of particular necessity and urgency in developing countries. Also, there has been somewhat less progress in wide-scale monitoring of personal exposures. However, it can be argued that with a significant future expansion of monitoring networks, including indoor environments, there may be less need for wearable or portable sensors/monitors to assess personal exposure. Traditional personal monitoring would still be valuable where spatial variability of pollutants of interest is at a finer resolution than the monitoring network can resolve.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A typology of reviews: an analysis of 14 review types and associated methodologies
Grant, M. J., & Booth, A. (2009) · Health Information & Libraries Journal · doi:10.1111/j.1471-1842.2009.00848.x · Cited by 10,817
Nanostructured Materials for Room‐Temperature Gas Sensors
Zhang, J., Liu, X., Neri, G., & Pinna, N. (2016) · Advanced Materials · doi:10.1002/adma.201503825 · Cited by 1,569
Self-citationA Survey on Gas Sensing Technology
Liu, X., Cheng, S., Liu, H., Hu, S., Zhang, D., & Ning, H. (2012) · Sensors · doi:10.3390/s120709635 · Cited by 1,416
Self-citationCastell, N., Dauge, F. R., Schneider, P., Vogt, M., Lerner, U., Fishbain, B., Broday, D., & Bartonova, A. (2017) · Environment International · doi:10.1016/j.envint.2016.12.007 · Cited by 1,039
Self-citationThe Changing Paradigm of Air Pollution Monitoring
Snyder, E. G., Watkins, T. H., Solomon, P. A., Thoma, E. D., Williams, R. W., Hagler, G. S. W., Shelow, D., Hindin, D. A., Kilaru, V. J., & Preuss, P. W. (2013) · Environmental Science & Technology · doi:10.1021/es4022602 · Cited by 974
Self-citationA Survey on Gas Sensing Technology
Liu, X., Cheng, S., Liu, H., Hu, S., Zhang, D., & Ning, H. (2012) · Cited by 926
Self-citationMead, M. I., Popoola, O. A. M., Stewart, G. B., Landshoff, P., Calleja, M., Hayes, M., Baldovi, J. J., McLeod, M. W., Hodgson, T. F., Dicks, J., et al. (2013) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.11.060 · Cited by 828
End-user perspective of low-cost sensors for outdoor air pollution monitoring
Rai, A. C., Kumar, P., Pilla, F., Skouloudis, A. N., Di Sabatino, S., Ratti, C., Yasar, A., & Rickerby, D. (2017) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.06.266 · Cited by 550
Self-citationJiao, W., Hagler, G., Williams, R., Sharpe, R., Brown, R., Garver, D., Judge, R., Caudill, M., Rickard, J., Davis, M., et al. (2016) · Atmospheric Measurement Techniques · doi:10.5194/amt-9-5281-2016 · Cited by 484
Self-citationSpinelle, L., Gerboles, M., Villani, M. G., Aleixandre, M., & Bonavitacola, F. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.03.031 · Cited by 474
Wang, Y., Li, J., Jing, H., Zhang, Q., Jiang, J., & Biswas, P. (2015) · Aerosol Science and Technology · doi:10.1080/02786826.2015.1100710 · Cited by 471
Spinelle, L., Gerboles, M., Kok, G., Persijn, S., & Sauerwald, T. (2017) · Sensors · doi:10.3390/s17071520 · Cited by 439
A Survey of Wireless Sensor Network Based Air Pollution Monitoring Systems
Yi, W., Lo, K., Mak, T., Leung, K., Leung, Y., & Meng, M. (2015) · Sensors · doi:10.3390/s151229859 · Cited by 388
Real-time air quality monitoring through mobile sensing in metropolitan areas
Devarakonda, S., Sevusu, P., Liu, H., Liu, R., Iftode, L., & Nath, B. (2013) · Proceedings of the 2nd ACM SIGKDD International Workshop on Urban Computing · doi:10.1145/2505821.2505834 · Cited by 362
Gao, M., Cao, J., & Seto, E. (2015) · Environmental Pollution · doi:10.1016/j.envpol.2015.01.013 · Cited by 345
Schneider, P., Castell, N., Vogt, M., Dauge, F. R., Lahoz, W. A., & Bartonova, A. (2017) · Environment International · doi:10.1016/j.envint.2017.05.005 · Cited by 340
Self-citationPersonal exposure monitoring of PM 2.5 in indoor and outdoor microenvironments
Steinle, S., Reis, S., Sabel, C. E., Semple, S., Twigg, M. M., Braban, C. F., Leeson, S. R., Heal, M. R., Harrison, D., Lin, C., et al. (2015) · Science of The Total Environment · doi:10.1016/j.scitotenv.2014.12.003 · Cited by 337
The next generation of low-cost personal air quality sensors for quantitative exposure monitoring
Piedrahita, R., Xiang, Y., Masson, N., Ortega, J., Collier, A., Jiang, Y., Li, K., Dick, R. P., Lv, Q., Hannigan, M., et al. (2014) · Atmospheric Measurement Techniques · doi:10.5194/amt-7-3325-2014 · Cited by 283
Deriving high-resolution urban air pollution maps using mobile sensor nodes
Hasenfratz, D., Saukh, O., Walser, C., Hueglin, C., Fierz, M., Arn, T., Beutel, J., & Thiele, L. (2015) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2014.11.008 · Cited by 282
Assessment of air quality microsensors versus reference methods: The EuNetAir joint exercise
Borrego, C., Costa, A. M., Ginja, J., Amorim, M., Coutinho, M., Karatzas, K., Sioumis, T., Katsifarakis, N., Konstantinidis, K., De Vito, S., et al. (2016) · Atmospheric Environment · doi:10.1016/j.atmosenv.2016.09.050 · Cited by 274
Baron, R., & Saffell, J. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00620 · Cited by 270
Low-Cost Air Quality Monitoring Tools: From Research to Practice (A Workshop Summary)
Clements, A. L., Griswold, W. G., RS, A., Johnston, J. E., Herting, M. M., Thorson, J., Collier-Oxandale, A., & Hannigan, M. (2017) · Sensors · doi:10.3390/s17112478 · Cited by 229
Inter-comparison of low-cost sensors for measuring the mass concentration of occupational aerosols
Sousan, S., Koehler, K., Thomas, G., Park, J. H., Hillman, M., Halterman, A., & Peters, T. M. (2016) · Aerosol Science and Technology · doi:10.1080/02786826.2016.1162901 · Cited by 220
On the feasibility of measuring urban air pollution by wireless distributed sensor networks
Moltchanov, S., Levy, I., Etzion, Y., Lerner, U., Broday, D. M., & Fishbain, B. (2015) · Science of The Total Environment · doi:10.1016/j.scitotenv.2014.09.059 · Cited by 217
Sousan, S., Koehler, K., Hallett, L., & Peters, T. M. (2016) · Aerosol Science and Technology · doi:10.1080/02786826.2016.1232859 · Cited by 210
Kumar, P., Skouloudis, A. N., Bell, M., Viana, M., Carotta, M. C., Biskos, G., & Morawska, L. (2016) · Science of The Total Environment · doi:10.1016/j.scitotenv.2016.04.032 · Cited by 201
Self-citationNanotechnology-Enabled Sensors
Kalantar-zadeh, K., & Fry, B. (2008) · Springer eBooks · doi:10.1007/978-0-387-68023-1 · Cited by 200
Jovašević-Stojanović, M., Bartonova, A., Topalović, D., Lazović, I., Pokrić, B., & Ristovski, Z. (2015) · Environmental Pollution · doi:10.1016/j.envpol.2015.08.035 · Cited by 176
Self-citationMetal oxide nanowire chemical sensors: innovation and quality of life
Comini, E. (2016) · Materials Today · doi:10.1016/j.mattod.2016.05.016 · Cited by 171
Laboratory Evaluation of the Shinyei PPD42NS Low-Cost Particulate Matter Sensor
Austin, E., Novosselov, I., Seto, E., & Yost, M. G. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137789 · Cited by 167
Mobile technologies and services for environmental monitoring: The Citi-Sense-MOB approach
Castell, N., Kobernus, M., Liu, H.-Y., Schneider, P., Lahoz, W., Berre, A. J., & Noll, J. (2015) · Urban Climate · doi:10.1016/j.uclim.2014.08.002 · Cited by 166
Molina, M. A., Gonzalez, F., Fletcher, A. T., & Doshi, A. A. (2015) · Sensors · doi:10.3390/s150819667 · Cited by 156
An improved PCA scheme for sensor FDI: Application to an air quality monitoring network
Harkat, M. F., Mourot, G., & Ragot, J. (2006) · Journal of Process Control · doi:10.1016/j.jprocont.2005.09.007 · Cited by 150
Characteristics and applications of small, portable gaseous air pollution monitors
McKercher, G. R., Salmond, J., & Vanos, J. (2017) · Environmental Pollution · doi:10.1016/j.envpol.2016.12.045 · Cited by 146
Jerrett, M., Donaire-González, D., Popoola, O., Jones, R. L., Cohen, R. C., Almanza, E., de Nazelle, A. J., Mead, M. I., Carrasco‐Turigas, G., Cole‐Hunter, T., et al. (2017) · Environmental Research · doi:10.1016/j.envres.2017.04.023 · Cited by 132
A low-cost particle counter as a realtime fine-particle mass monitor
Northcross, A., Edwards, R. D., Johnson, M. A., Wang, Z.-M., Zhu, K., Allen, T., & Smith, K. R. (2012) · Environmental Science Processes & Impacts · doi:10.1039/c2em30568b · Cited by 124
Williams, D. E., Henshaw, G. S., Bart, M., Laing, G., Wagner, J., Naisbitt, S. C., & Salmond, J. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/6/065803 · Cited by 103
Using a new, low-cost air quality sensor to quantify second-hand smoke (SHS) levels in homes
Semple, S. E., Ibrahim, T. A. E., Apsley, A., Steiner, M. F. C., & Turner, S. (2013) · Tobacco Control · doi:10.1136/tobaccocontrol-2013-051188 · Cited by 91
Miniaturized Monitors for Assessment of Exposure to Air Pollutants: A Review
Borghi, F., Spinazzè, A., Rovelli, S., Campagnolo, D., Buono, L. D., Cattaneo, A., & Cavallo, D. M. (2017) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph14080909 · Cited by 91
Dacunto, P. J., Klepeis, N. E., Cheng, K.-C., Acevedo-Bolton, V., Jiang, R.-T., Repace, J., Ott, W. R., & Hildemann, L. M. (2015) · Environmental Science Processes & Impacts · doi:10.1039/c5em00365b · Cited by 75
A real-time ambient air quality monitoring wireless sensor network for schools in smart cities
Ali, H., Soe, J. K., & Weller, S. R. (2015) · IEEE International Smart Cities Conference (ISC2) · doi:10.1109/isc2.2015.7366163 · Cited by 74
Protocol of evaluation and calibration of low-cost gas sensors for the monitoring of air pollution
Spinelle, L., Aleixandre, M., & Gerboles, M. (2013) · Joint Research Centre (European Commission) · doi:10.2788/9916 · Cited by 69
Polluino: An efficient cloud-based management of IoT devices for air quality monitoring
Fioccola, G. B., Sommese, R., Tufano, I., Canonico, R., & Ventre, G. (2016) · IEEE International Forum on Research and Technology for Society and Industry (RTSI) · doi:10.1109/rtsi.2016.7740617 · Cited by 69
Use of real-time sensors to characterise human exposures to combustion related pollutants
Delgado-Saborit, J. M. (2012) · Journal of Environmental Monitoring · doi:10.1039/c2em10996d · Cited by 60
Woodall, G. M., Hoover, M. D., Williams, R. W., Benedict, K., Harper, M., Soo, J., Jarabek, A. M., Stewart, M. J., Brown, J. S., Hulla, J., et al. (2017) · Atmosphere · doi:10.3390/atmos8100182 · Cited by 58
Self-citationJohnson, K. K., Bergin, M., Russell, A. G., & Hagler, G. S. W. (2016) · doi:10.5194/amt-2015-331 · Cited by 47
Self-citationPersonal monitoring of ozone exposure: A fully portable device for under $150 USD cost
Cao, T., & Thompson, J. E. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.10.090 · Cited by 35
Weissert, L. F., Salmond, J., Miskell, G., Alavi, M., Grange, S. K., Henshaw, G. S., & Williams, D. E. (2016) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2016.09.229 · Cited by 35
View: implementing low cost air quality monitoring solution for urban areas
Ikram, J., Tahir, A., Kazmi, H., et al. (2012) · ENVIRONMENTAL SYSTEMS RESEARCH · doi:10.1186/2193-2697-1-10 · Cited by 33
A wireless system for indoor air quality monitoring
du Plessis, R., Kumar, A., Gp, H., et al. (2016) · Proceedings of the Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2016.7794087 · Cited by 27
Zhang, R., Ravì, D., Yang, G., & Lo, B. P. L. (2017) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2017.7936020 · Cited by 16
Mobile Wireless System for Outdoor Air Quality Monitoring
Коваль, А. В., & Irigoyen, E. (2016) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-47364-2_33 · Cited by 11
Cited by
Hao, L.-N., Umar, M., Khan, Z., & Ali, W. (2021) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.141853 · Cited by 785
Giordano, M. R., Malings, C., Pandis, S. N., Presto, A. A., McNeill, V. F., Westervelt, D. M., Beekmann, M., & Subramanian, R. (2021) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2021.105833 · Cited by 426
Barkjohn, K. K., Gantt, B., & Clements, A. L. (2021) · Atmospheric Measurement Techniques · doi:10.5194/amt-14-4617-2021 · Cited by 392
Internet of Things Mobile–Air Pollution Monitoring System (IoT-Mobair)
Dhingra, S., Madda, R. B., Gandomi, A. H., Patan, R., & Daneshmand, M. (2019) · IEEE Internet of Things Journal · doi:10.1109/jiot.2019.2903821 · Cited by 368
Advances in air quality research – current and emerging challenges
Sokhi, R. S., Moussiopoulos, N., Baklanov, A., Bartzis, J., Coll, I., Finardi, S., Friedrich, R., Geels, C., Grönholm, T., Halenka, T., et al. (2022) · Atmospheric Chemistry and Physics · doi:10.5194/acp-22-4615-2022 · Cited by 285
Metadata
- Authors
- Morawska, L., Thai, P. K., Liu, X., Asumadu-Sakyi, A., Ayoko, G., Bartonova, A., Bedini, A., Chai, F., Christensen, B., Dunbabin, M., Gao, J., Hagler, G. S. W., Jayaratne, R., Kumar, P., Lau, A. K. H., Louie, P. K. K., Mazaheri, M., Ning, Z., Motta, N., Mullins, B., Rahman, M. M., Ristovski, Z., Shafiei, M., Tjondronegoro, D., Westerdahl, D., & Williams, R.
- Venue
- Environment International
- Publisher
- Elsevier BV
- Published
- 2018-07
- Volume
- 116
- Pages
- 286-299
- ISSN
- 0160-4120 (ISSN-L)
- OpenAlex
- W2797612288
- Cited by
- 864
- References
- 52
- FWCI
- 37.62
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.