Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 471

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Laboratory Evaluation and Calibration of Three Low-Cost Particle Sensors for Particulate Matter Measurement

Open access
Wang, Yang, Li, Jiayu, Jing, He, Zhang, Qiang, Jiang, Jingkun, Biswas, Pratim·2015·Aerosol Science and Technology

Abstract

Particle sensors offer significant advantages of compact size and low cost, and have recently drawn great attention for usage as portable monitors measuring particulate matter mass concentrations. However, most sensor systems have not been thoroughly evaluated with standardized calibration protocols, and their data quality is not well documented. In this work, three low-cost particle sensors based on light scattering (Shinyei PPD42NS, Samyoung DSM501A, and Sharp GP2Y1010AU0F) were evaluated by calibration methods adapted from the US EPA 2013 Air Sensor Workshop recommendations. With a SidePak (TSI Inc., St. Paul, MN, USA), a scanning mobility particle sizer (TSI Inc.), and an AirAssure™ PM2.5 Indoor Air Quality Monitor (TSI Inc.), which itself relies on a GP2Y1010AU0F sensor as reference instruments, six performance aspects were examined: linearity of response, precision of measurement, limit of detection, dependence on particle composition, dependence on particle size, and relative humidity and temperature influences. This work found that: (a) all three sensors demonstrated high linearity against SidePak measured concentrations, with R2 values higher than 0.8914 in the particle concentration range of 0–1000 μg/m3, and the linearity depended on the studied range of particle concentrations; (b) the standard deviations of the sensors varied from 15 to 90 μg/m3 for a concentration range of 0–1000 μg/m3; (c) the outputs of all three sensors depended highly on particle composition and size, resulting in as high as 10 times difference in the sensor outputs; and (d) humidity affected the sensor response. This article provides further recommendations for applications of the three tested sensors.Copyright 2015 American Association for Aerosol Research

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/02786826.2015.1100710

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 471

Metadata

Authors
Wang, Y., Li, J., Jing, H., Zhang, Q., Jiang, J., & Biswas, P.
Venue
Aerosol Science and Technology
Published
2015-10-19
Volume
49
Issue
11
Pages
1063-1077
ISSN
  • 0278-6826 (ISSN-L)
  • 1521-7388
OpenAlex
W2177101396
Cited by
471
References
2
FWCI
16.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Laboratory Evaluation and Calibration of Three Low-Cost Particle Sensors for Particulate Matter Measurement. https://app.cochat.ai/papers/10.1080/02786826.2015.1100710
The paper
Wang, Y., Li, J., Jing, H., Zhang, Q., Jiang, J., & Biswas, P. (2015). Laboratory Evaluation and Calibration of Three Low-Cost Particle Sensors for Particulate Matter Measurement. Aerosol Science and Technology. https://doi.org/10.1080/02786826.2015.1100710

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.