The DOI matches its Crossref record.
Current limiting algorithms and transient stability analysis of grid-forming VSCs
Open accessAbstract
This paper consists first in comparing the well-known virtual impedance and current saturation algorithms in case of a three-phase short circuit. During the fault, the virtual impedance has an indirect action on the AC current since it depends mainly on the AC voltage controllers dynamics, whereas, the current saturation algorithm has a direct action on the AC current. Thus, a first study consists in comparing the dynamic behavior of the AC current for both methods separately. Once the fault is cleared, the grid-forming converter should be able to resynchronize to the main grid. In this paper, the impact of each current limiting algorithm on the transient stability is highlighted. Based on this comparative approach between the virtual impedance and the current saturation algorithms, a hybrid current limiting control is proposed to benefit the advantages of each algorithm in terms of current limitation and transient stability. To show the effectiveness of the proposed control, time-domain simulations and experimental test cases have been performed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Grid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
A Review of Current-Limiting Control of Grid-Forming Inverters Under Symmetrical Disturbances
Fan, B., Liu, T., Zhao, F., Wu, H., & Wang, X. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3227507 · Cited by 371
Rokrok, E., Qoria, T., Bruyere, A., Francois, B., & Guillaud, X. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2021.3107959 · Cited by 311
Self-citationOvercurrent Limiting in Grid-Forming Inverters: A Comprehensive Review and Discussion
Baeckeland, N., Chatterjee, D., Lu, M., Johnson, B., & Seo, G.-S. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3430316 · Cited by 271
Liu, T., Wang, X., Liu, F., Xin, K., & Liu, Y. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3122744 · Cited by 200
Metadata
- Authors
- Qoria, T., Gruson, F., Colas, F., Kestelyn, X., & Guillaud, X.
- Venue
- Electric Power Systems Research
- Publisher
- Elsevier BV
- Published
- 2020-12
- Volume
- 189
- Pages
- 106726
- ISSN
- 0378-7796 (ISSN-L)
- OpenAlex
- W3047876507
- Cited by
- 249
- References
- 0
- FWCI
- 11.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Current limiting algorithms and transient stability analysis of grid-forming VSCs. https://app.cochat.ai/papers/10.1016/j.epsr.2020.106726
- The paper
- Qoria, T., Gruson, F., Colas, F., Kestelyn, X., & Guillaud, X. (2020). Current limiting algorithms and transient stability analysis of grid-forming VSCs. Electric Power Systems Research. https://doi.org/10.1016/j.epsr.2020.106726
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.