A deep learning approach for real-time detection of atrial fibrillation
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Abstract Goal: To develop a robust and real-time approach for automatic detection of atrial fibrillation (AF) in long-term electrocardiogram (ECG) recordings using deep learning (DL). Method: An end-to-end model combining the Convolutional- and Recurrent-Neural Networks (CNN and RNN) was proposed to extract high level features from segments of RR intervals (RRIs) in order to classify them as AF or normal sinus rhythm (NSR). Results: The model was trained and validated on three different databases including a total of 89 subjects. It achieved a sensitivity and specificity of 98.98% and 96.95%, respectively, validated through a 5-fold cross-validation. Additionally, the proposed model was found to be computationally efficient and it was capable of analyzing 24 h of ECG recordings in less than one second. The proposed algorithm was also tested on the unseen datasets to examine its robustness in detecting AF for new recordings which resulted in 98.96% and 86.04% for specificity and sensitivity, respectively. Conclusion: Compared to the state-of-the-art models evaluated on standard benchmark ECG datasets, the proposed model produced better performance in detecting AF. Additionally, since the model learns features directly from the data, it avoids the need for clever/cumbersome feature engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Delving Deep into Rectifiers: Surpassing Human-Level Performance on ImageNet Classification
He, K., Zhang, X., Ren, S., & Sun, J. (2015) · 2015 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2015.123 · Cited by 19,741
Proceedings of IEEE Conference on Computer Vision and Pattern Recognition
(1993) · doi:10.1109/cvpr.1993 · Cited by 17,667
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Proceedings of IEEE International Conference on Computer Vision
(1995) · Proceedings of IEEE International Conference on Computer Vision · doi:10.1109/iccv.1995.466933 · Cited by 12,860
(2016) · Cited by 11,679
Empirical Evaluation of Gated Recurrent Neural Networks on Sequence Modeling
Chung, J., Gulcehre, C., Cho, K., & Bengio, Y. (2014) · arXiv · doi:10.48550/arxiv.1412.3555 · Cited by 11,008 · cited 1×
“Intuitively, this is an important property, as the network is capable of remembering features from early stages of a sequence and hence capture 110 long-term dependencies (Chung et al., 2014).”
Background
Cited by
A review on the long short-term memory model
Van Houdt, G., Mosquera, C., & Nápoles, G. (2020) · Artificial Intelligence Review · doi:10.1007/s10462-020-09838-1 · Cited by 1,991
Hong, S., Zhou, Y., Shang, J., Xiao, C., & Sun, J. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103801 · Cited by 464
A review on deep learning methods for ECG arrhythmia classification
Ebrahimi, Z., Loni, M., Daneshtalab, M., & Gharehbaghi, A. (2020) · Expert Systems with Applications: X · doi:10.1016/j.eswax.2020.100033 · Cited by 447
Deep learning in ECG diagnosis: A review
Liu, X., Wang, H., Li, Z., & Qin, L. (2021) · Knowledge-Based Systems · doi:10.1016/j.knosys.2021.107187 · Cited by 436
Automated Atrial Fibrillation Detection using a Hybrid CNN-LSTM Network on Imbalanced ECG Datasets
Petmezas, G., Haris, K., Stefanopoulos, L., Kilintzis, V., Tzavelis, A., Rogers, J. A., Katsaggelos, A. K., & Maglaveras, N. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102194 · Cited by 333
Murat, F., Yildirim, O., Talo, M., Baloglu, U. B., Demir, Y., & Acharya, U. R. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103726 · Cited by 326
A Hybrid Deep Learning Approach for ECG-Based Arrhythmia Classification
Madan, P., Singh, V., Singh, D. P., Diwakar, M., Pant, B., & Kishor, A. (2022) · Bioengineering · doi:10.3390/bioengineering9040152 · Cited by 181
“Model Architecture and Details There are several methods to automatically analyse ECG, including machine learningbased [48,49] and deep learning-based [34,50,51].”
MethodDENS-ECG: A deep learning approach for ECG signal delineation
Peimankar, A., & Puthusserypady, S. (2021) · Expert Systems with Applications · doi:10.1016/j.eswa.2020.113911 · Cited by 174
Self-citationBizopoulos, P., & Koutsouris, D. (2019) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2885714 · Cited by 163
“[89] converted ECG signals from AFDB, into RR intervals to classify them for AF detection.”
MethodDiagnosis of Atrial Fibrillation Based on AI-Detected Anomalies of ECG Segments
Choi, S., Choi, K., Yun, H. K., Kim, S. H., Choi, H.-H., Park, Y.-S., & Joo, S. (2024) · Heliyon · doi:10.1016/j.heliyon.2023.e23597 · Cited by 15
Metadata
- Authors
- Andersen, R. S., Peimankar, A., & Puthusserypady, S.
- Venue
- Expert Systems with Applications
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 115
- Pages
- 465-473
- ISSN
- 0957-4174 (ISSN-L)
- OpenAlex
- W2886982273
- Cited by
- 402
- References
- 48
- FWCI
- 23.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.