Abstract

AIMS: Effects of cardiac resynchronization therapy (CRT) in patients with right ventricular pacing and congestive heart failure (CHF) have only been reported in limited series. CRT in patients with atrial fibrillation remains controversial. Patients with AV junctional ablation offer a unique opportunity to study the effects of CRT in patients with right ventricular pacing combined with atrial fibrillation. The aims of the present study were to evaluate the effects of upgrading to biventricular pacing patients with CHF, permanent atrial fibrillation, and prior ablation of the atrioventricular (AV) junction followed by conventional right ventricular pacing. METHODS AND RESULTS: We studied 16 consecutive patients with permanent atrial fibrillation treated by AV junctional ablation. After a mean follow-up of 20+/-19 months (6 weeks to 5 years) they were successfully upgraded to biventricular pacing for severe CHF. Parameters were prospectively evaluated at baseline and at 6 months. The 14 surviving patients at 6 months demonstrated significant improvement (P<0.02) in New York Heart Association class but the exercise test parameters remained unchanged. Cardiothoracic ratio decreased by 5% (P=0.04), end-systolic diameter by 8% (P=0.001), end-diastolic diameter by 4% (P=0.08), systolic pulmonary artery pressure by 17% (P<0.0001) and mitral regurgitation area by 40% (P<0.05). Ejection fraction increased by 17% (P=0.11) and fractional shortening by 24% (P=0.01). CONCLUSION: CRT improves left ventricular performance and functional status in patients with permanent atrial fibrillation and prior remote right ventricular pacing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.eupc.2004.04.004

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 118

Metadata

Authors
VALLSBERTAULT, V
Venue
Europace
Published
2004-09
Volume
6
Issue
5
Pages
438-443
ISSN
1099-5129 (ISSN-L)
OpenAlex
W2166022387
Cited by
118
References
2
FWCI
7.23
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of upgrading to biventricular pacing in patients with right ventricular pacing and congestive heart failure after atrioventricular junctional ablation for chronic atrial fibrillation. https://app.cochat.ai/papers/10.1016/j.eupc.2004.04.004
The paper
VALLSBERTAULT, V. (2004). Assessment of upgrading to biventricular pacing in patients with right ventricular pacing and congestive heart failure after atrioventricular junctional ablation for chronic atrial fibrillation. Europace. https://doi.org/10.1016/j.eupc.2004.04.004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.