CoChat

Application of transcranial magnetic stimulation for major depression: Coil design and neuroanatomical variability considerations

Open access
Zibman, Samuel, Pell, Gaby S., Barnea-Ygael, Noam, Roth, Yiftach, Zangen, Abraham · 2021 · European Neuropsychopharmacology
Cited by 63

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

High-frequency repeated transcranial magnetic stimulation (rTMS) as a treatment for major depressive disorder (MDD) has received FDA clearance for both the figure-of-8 coil (figure-8 coil) and the H1 coil. The FDA-cleared MDD protocols for both coils include high frequency (10-18 Hz) stimulation targeting the dorsolateral prefrontal cortex (dlPFC) at an intensity that is 120% of the right-hand resting motor threshold. Despite these similar parameters, the two coils generate distinct electrical fields (e-fields) which result in differences in the cortical stimulation they produce. Due to the differences in coil designs, the H1 coil induces a stimulation e-field that is broader and deeper than the one induced by the figure-8 coil. In this paper we review theoretical and clinical implications of these differences between the two coils and compare evidence of their safety and efficacy in treating MDD. We present the design principles of the coils, the challenges of identifying, finding, and stimulating the optimal brain target of each individual (both from functional and connectivity perspectives), and the possible implication of stimulating outside that target. There is only one study that performed a direct comparison between clinical effectiveness of the two coils, using the standard FDA-approved protocols in MDD patients. This study indicated clinical superiority of the H1 coil but did not measure long-term effects. Post-marketing data suggest that both coils have a similar safety profile in clinical practice, whereas effect size comparisons of the two respective FDA pivotal trials suggests that the H1 coil may have an advantage in efficacy. We conclude that further head-to-head experiments are needed, especially ones that will compare long-term effects and usage of similar temporal stimulation parameters and similar number of pulses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.euroneuro.2019.06.009

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 63

Metadata

Authors
Zibman, S., Pell, G. S., Barnea-Ygael, N., Roth, Y., & Zangen, A.
Venue
European Neuropsychopharmacology
Publisher
Elsevier BV
Published
2021-04
Volume
45
Pages
73-88
ISSN
0924-977X (ISSN-L)
OpenAlex
W2954753368
Cited by
63
References
21
FWCI
1.57
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Application of transcranial magnetic stimulation for major depression: Coil design and neuroanatomical variability considerations. https://app.cochat.ai/papers/10.1016/j.euroneuro.2019.06.009
The paper
Zibman, S., Pell, G. S., Barnea-Ygael, N., Roth, Y., & Zangen, A. (2021). Application of transcranial magnetic stimulation for major depression: Coil design and neuroanatomical variability considerations. European Neuropsychopharmacology. https://doi.org/10.1016/j.euroneuro.2019.06.009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.