The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Hydrogel microparticles for biosensing
Open accessAbstract
Due to their hydrophilic, biocompatible, and highly tunable nature, hydrogel materials have attracted strong interest in the recent years for numerous biotechnological applications. In particular, their solution-like environment and non-fouling nature in complex biological samples render hydrogels as ideal substrates for biosensing applications. Hydrogel coatings, and later, gel dot surface microarrays, were successfully used in sensitive nucleic acid assays and immunoassays. More recently, new microfabrication techniques for synthesizing encoded particles from hydrogel materials have enabled the development of hydrogel-based suspension arrays. Lithography processes and droplet-based microfluidic techniques enable generation of libraries of particles with unique spectral or graphical codes, for multiplexed sensing in biological samples. In this review, we discuss the key questions arising when designing hydrogel particles dedicated to biosensing. How can the hydrogel material be engineered in order to tune its properties and immobilize bioprobes inside? What are the strategies to fabricate and encode gel particles, and how can particles be processed and decoded after the assay? Finally, we review the bioassays reported so far in the literature that have used hydrogel particle arrays and give an outlook of further developments of the field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology
Peppas, N. A., Hilt, J. Z., Khademhosseini, A., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501612 · Cited by 4,109
Designing materials for biology and medicine
Langer, R., & Tirrell, D. A. (2004) · Nature · doi:10.1038/nature02388 · Cited by 3,198
Photopolymerizable hydrogels for tissue engineering applications
Nguyen, K. T., & West, J. L. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00175-8 · Cited by 1,669
Ma, C., Fan, R., Ahmad, H., Shi, Q., Comin-Anduix, B., Chodon, T., Koya, R. C., Liu, C.-C., Kwong, G. A., Radu, C. G., et al. (2011) · Nature Medicine · doi:10.1038/nm.2375 · Cited by 441 · cited 1×
“There has also been a parallel effort towards the creation of novel device geometries for high throughput single-cell analysis [141, 142].”
Cited by
Microfluidic fabrication of microparticles for biomedical applications
Li, W., Zhang, L., Ge, X., Xu, B., Zhang, W., Qu, L., Choi, C.-H., Xu, J., Zhang, A., Lee, H., et al. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00263g · Cited by 585
Metadata
- Authors
- Le Goff, G. C., Srinivas, R. L., Hill, W. A., & Doyle, P. S.
- Venue
- European Polymer Journal
- Publisher
- Elsevier BV
- Published
- 2015-11
- Volume
- 72
- Pages
- 386-412
- ISSN
- 0014-3057 (ISSN-L)
- OpenAlex
- W2038569827
- Cited by
- 200
- References
- 4
- FWCI
- 7.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hydrogel microparticles for biosensing. https://app.cochat.ai/papers/10.1016/j.eurpolymj.2015.02.022
- The paper
- Le Goff, G. C., Srinivas, R. L., Hill, W. A., & Doyle, P. S. (2015). Hydrogel microparticles for biosensing. European Polymer Journal. https://doi.org/10.1016/j.eurpolymj.2015.02.022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.