CoChat

The Stockholm-3 Model for Prostate Cancer Detection: Algorithm Update, Biomarker Contribution, and Reflex Test Potential

Open access
Ström, Peter, Nordström, Tobias, Aly, Markus, Egevad, Lars, Grönberg, Henrik, Eklund, Martin · 2018 · European Urology
Cited by 110

The DOI matches its Crossref record.

Abstract

BACKGROUND: It has been shown that the Stockholm-3 model (S3M) outperforms prostate-specific antigen (PSA) as a screening tool for prostate cancer. OBJECTIVE: To update the S3M, to give a detailed account of the value of each predictor in the S3M, and to evaluate the S3M as a reflex test for men with PSA ≥3ng/ml. DESIGN, SETTING, AND PARTICIPANTS: During 2012-2015, the Stockholm-3 study evaluated the S3M relative to PSA as tests for Gleason score ≥7 prostate cancers among men aged 50-69 yr. The participants (n=59 159) underwent both tests, and biopsy was recommended if at least one was positive. A total of 5073 men had a biopsy because of elevated PSA (≥3ng/ml). OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Logistic regression was used to update the S3M: intact PSA was removed, HOXB13 was included, and the model was fitted to data from the Stockholm-3 training and validation cohorts. To compare S3M with PSA, we fixed the sensitivity for detection of high-grade cancer and evaluated the performance as the number of biopsies needed to achieve that sensitivity for each test. RESULTS AND LIMITATIONS: The updated S3M slightly improved the area under the receiver operating characteristic curve compared to previously published results (0.75 vs 0.74). When used as a reflex test for men with PSA ≥3ng/ml, S3M reduced the number of biopsies needed by 34% compared to the use of PSA alone, with equal sensitivity. A limitation is the ethnically homogeneous population. CONCLUSIONS: A major problem with PSA screening-too many unnecessary biopsies-can be mitigated if S3M is used as a reflex test. PATIENT SUMMARY: To find aggressive prostate cancer with the minimum number of negative biopsies and detection of clinically insignificant cancers, we evaluated the use of a personalized diagnostic prediction model as a second test for men with a positive prostate-specific antigen (PSA) test. We found that this two-step approach could reduce prostate biopsies by a third compared to using PSA alone.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.eururo.2017.12.028

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 110

Metadata

Authors
Ström, P., Nordström, T., Aly, M., Egevad, L., Grönberg, H., & Eklund, M.
Venue
European Urology
Publisher
Elsevier BV
Published
2018-08
Volume
74
Issue
2
Pages
204-210
ISSN
0302-2838 (ISSN-L)
OpenAlex
W2783064736
Cited by
110
References
0
FWCI
9.64
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Stockholm-3 Model for Prostate Cancer Detection: Algorithm Update, Biomarker Contribution, and Reflex Test Potential. https://app.cochat.ai/papers/10.1016/j.eururo.2017.12.028
The paper
Ström, P., Nordström, T., Aly, M., Egevad, L., Grönberg, H., & Eklund, M. (2018). The Stockholm-3 Model for Prostate Cancer Detection: Algorithm Update, Biomarker Contribution, and Reflex Test Potential. European Urology. https://doi.org/10.1016/j.eururo.2017.12.028

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.