Prostate Magnetic Resonance Imaging, with or Without Magnetic Resonance Imaging-targeted Biopsy, and Systematic Biopsy for Detecting Prostate Cancer: A Cochrane Systematic Review and Meta-analysis

Open access
Drost, Frank-Jan H., Osses, Daniel, Nieboer, Daan, Bangma, Chris H., Steyerberg, Ewout W., Roobol, Monique J., Schoots, Ivo G.·2020·European Urology

Abstract

CONTEXT Magnetic resonance imaging (MRI), with or without MRI-targeted biopsy (MRI pathway), is an alternative test to systematic transrectal ultrasonography-guided biopsy in men suspected of having prostate cancer. At present, evidence on which test to use is insufficient to inform detailed evidence-based decision making. OBJECTIVE To determine the diagnostic accuracy of the index tests MRI only, MRI-targeted biopsy, MRI pathway, and systematic biopsy, as compared with template-guided biopsy (reference standard), in detecting clinically significant prostate cancer, defined as International Society of Urological Pathology grade 2 or higher, in biopsy-naive men or those with a prior-negative biopsy (or mix of both). EVIDENCE ACQUISITION We systematically searched the literature and considered for inclusion any cross-sectional study if it investigated (1) one or more index tests verified by the reference standard, and (2) paired testing of the MRI pathway with systematic biopsy. Quality and certainty of evidence were assessed by the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) and Grading of Recommendations Assessment, Development and Evaluation, respectively. EVIDENCE SYNTHESIS Accuracy analyses: Using a baseline cancer prevalence of 30%, MRI pathway (sensitivity 0.72 [95% confidence interval {CI}: 0.60-0.82]; specificity 0.96 [0.94-0.98]; eight studies) may result in 216 (180-246) true positives, 28 (14-42) false positives, 672 (658-686) true negatives, and 84 (54-120) false negatives per 1000 men. Systematic biopsy (sensitivity 0.63 [0.19-0.93]; specificity 1.00 [0.91-1.00]; four studies) may result in 189 (57-279) true positives, 0 (0-63) false positives, 700 (637-700) true negatives, and 111 (21-243) false negatives per 1000 men. Agreement analyses: With a direct comparison of the MRI pathway with systematic biopsy concerning significant disease, we found pooled detection ratios of 1.05 (95% CI: 0.95-1.16; 20 studies) in biopsy-naive men and 1.44 (1.19-1.75; 10 studies) in men with a prior-negative biopsy. Concerning insignificant disease, we found detection ratios of 0.63 (95% CI: 0.54-0.74), and 0.62 (95% CI: 0.44-0.88), respectively. CONCLUSIONS MRI pathway had the most favourable outcome in significant and insignificant prostate cancer detection compared with systematic biopsy. The certainty in our findings was reduced by study limitations. PATIENT SUMMARY We reviewed recent advances in prostate biopsy by magnetic resonance imaging (MRI) guidance and targeting for prostate cancer detection in comparison with standard diagnosis by systematic biopsies. The findings of this Cochrane review suggest that MRI pathway is better than systematic biopsies in making a correct diagnosis of clinically important prostate cancer and reducing redundant biopsies and the detection of unimportant cancers substantially. However, MRI pathway still misses some men with important prostate cancer. Therefore, further research in this area is important.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.eururo.2019.06.023

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

See all 370

Metadata

Authors
Drost, F.-J. H., Osses, D., Nieboer, D., Bangma, C. H., Steyerberg, E. W., Roobol, M. J., & Schoots, I. G.
Venue
European Urology
Publisher
Elsevier BV
Published
2020-01
Volume
77
Issue
1
Pages
78-94
ISSN
0302-2838 (ISSN-L)
OpenAlex
W2960844714
Cited by
370
References
31
FWCI
9.95
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prostate Magnetic Resonance Imaging, with or Without Magnetic Resonance Imaging-targeted Biopsy, and Systematic Biopsy for Detecting Prostate Cancer: A Cochrane Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.1016/j.eururo.2019.06.023
The paper
Drost, F.-J. H., Osses, D., Nieboer, D., Bangma, C. H., Steyerberg, E. W., Roobol, M. J., & Schoots, I. G. (2020). Prostate Magnetic Resonance Imaging, with or Without Magnetic Resonance Imaging-targeted Biopsy, and Systematic Biopsy for Detecting Prostate Cancer: A Cochrane Systematic Review and Meta-analysis. European Urology. https://doi.org/10.1016/j.eururo.2019.06.023

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.