The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Extracellular matrix turnover and outflow resistance
Open accessAbstract
Normal homeostatic adjustment of elevated intraocular pressure (IOP) involves remodeling the extracellular matrix (ECM) of the trabecular meshwork (TM). This entails sensing elevated IOP, releasing numerous activated proteinases to degrade existing ECM and concurrent biosynthesis of replacement ECM components. To increase or decrease IOP, the quantity, physical properties and/or organization of new components should be somewhat different from those replaced in order to modify outflow resistance. ECM degradation and replacement biosynthesis in the outflow pathway must be tightly controlled and focused to retain the complex structural organization of the tissue. Recently identified podosome- or invadopodia-like structures (PILS) may aid in the focal degradation of ECM and organization of replacement components.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
TIMP-3 Binds to Sulfated Glycosaminoglycans of the Extracellular Matrix
Yu, W.-H., Yu, S.-S. C., Meng, Q., Brew, K., & Woessner, J. F. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.m000907200 · Cited by 328
Cited by
The trabecular meshwork outflow pathways: Structural and functional aspects
Tamm, E. R. (2009) · Experimental Eye Research · doi:10.1016/j.exer.2009.02.007 · Cited by 490
Vranka, J. A., Kelley, M. J., Acott, T. S., & Keller, K. E. (2015) · Experimental Eye Research · doi:10.1016/j.exer.2014.07.014 · Cited by 393
Self-citationMyofibroblast transdifferentiation: The dark force in ocular wound healing and fibrosis
Shu, D. Y., & Lovicu, F. J. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.08.001 · Cited by 387
Current understanding of conventional outflow dysfunction in glaucoma
Stamer, W. D., & Acott, T. S. (2012) · Current Opinion in Ophthalmology · doi:10.1097/icu.0b013e32834ff23e · Cited by 320
Self-citationAqueous outflow - A continuum from trabecular meshwork to episcleral veins
Carreon, T., van der Merwe, E., Fellman, R. L., Johnstone, M., & Bhattacharya, S. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.12.004 · Cited by 312
Metadata
- Authors
- Keller, K. E., Aga, M., Bradley, J. M., Kelley, M. J., & Acott, T. S.
- Venue
- Experimental Eye Research
- Publisher
- Elsevier BV
- Published
- 2009-04
- Volume
- 88
- Issue
- 4
- Pages
- 676-682
- ISSN
- 0014-4835 (ISSN-L)
- OpenAlex
- W2047400044
- Cited by
- 234
- References
- 1
- FWCI
- 6.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Extracellular matrix turnover and outflow resistance. https://app.cochat.ai/papers/10.1016/j.exer.2008.11.023
- The paper
- Keller, K. E., Aga, M., Bradley, J. M., Kelley, M. J., & Acott, T. S. (2009). Extracellular matrix turnover and outflow resistance. Experimental Eye Research. https://doi.org/10.1016/j.exer.2008.11.023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.