CoChat

Investigating impacts of surface charge on intraocular distribution of intravitreal lipid nanoparticles

Huang, Xiaonan, Chau, Ying · 2019 · Experimental Eye Research
Cited by 35

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

In this paper, the effect of surface charge of intravitreal lipid nanoparticles (LNPs) on their intraocular accumulation and distribution was quantitatively and systematically studied. The retinal distribution of LNPs delivering model drug (siRNA) with optimal surface charge was visualized as well. LNPs and siRNA-loaded LNPs (siLNPs) were prepared with ethanol-injection method. C57BL/6 Mice with the age of 6-8 weeks were used for the animal experiments. Quantitative accumulation in the eye and respective intraocular distribution of the intravitreally injected LNPs with different surface charge were examined after predesignated time points. The fluorescence intensity of the fluorescent labeled siRNA was also quantified based on the confocal microscope images. The release of siRNA from siLNPs was studied in mimicked vitreous environment at 37 °C with the presence of 50% serum protein. We successfully prepared six types of LNPs had relatively uniform size around 70 nm and varied in zeta potential ranging from -30 mV to +50 mV. Negative, neutral and slightly positive charged LNPs were cleared much faster than strongly positive charged LNPs from the mice's eyes. After 6 h, LNPs with zeta potential of +35 mV had highest ratio of retinal to vitreous accumulation and penetrated through the entire layer of the retina. The siLNPs could successfully deliver the siRNA to the ganglion cells and inner plexiform layer of the retina. After 24 h, majority of LNPs and siLNPs were cleared, suggesting that the LNPs with pegylated surface in the absence of any targeting ligand were not internalized by retinal cells. The mechanism of how the surface charge of nanoparticles affects their intraocular retention and distribution was intensively discussed. The results suggested that intravitreally injected LNPs with optimal surface charge around +35 mV can distribute and penetrate the retina, which could be further modified as promising nanocarriers for retinal delivery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.exer.2019.107711

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 35

Metadata

Authors
Huang, X., & Chau, Y.
Venue
Experimental Eye Research
Publisher
Elsevier BV
Published
2019-09
Volume
186
Pages
107711
ISSN
0014-4835 (ISSN-L)
OpenAlex
W2952752697
Cited by
35
References
3
FWCI
1.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Investigating impacts of surface charge on intraocular distribution of intravitreal lipid nanoparticles. https://app.cochat.ai/papers/10.1016/j.exer.2019.107711
The paper
Huang, X., & Chau, Y. (2019). Investigating impacts of surface charge on intraocular distribution of intravitreal lipid nanoparticles. Experimental Eye Research. https://doi.org/10.1016/j.exer.2019.107711

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.