Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 355

The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.

The sit-to-stand muscle power test: An easy, inexpensive and portable procedure to assess muscle power in older people

Open access
Alcazar, Julian, Losa-Reyna, Jose, Rodriguez-Lopez, Carlos, Alfaro-Acha, Ana, Rodriguez-Mañas, Leocadio, Ara, Ignacio, García-García, Francisco J., Alegre, Luis M.·2018·Experimental Gerontology

Abstract

Introduction: Skeletal muscle power has been demonstrated to be a stronger predictor of functional limitations than any other physical capability. However, no validated alternatives exist to the usually expensive instruments and/or time‐consuming methods to evaluate muscle power in older populations. Our aim was to validate an easily applicable procedure to assess muscle power in large cohort studies and the clinical setting and to assess its association with other age‐related outcomes. Methods: Forty community dwelling older adults (70–87years) and 1804 older subjects (67–101years) participating in the Toledo Study for Healthy Aging were included in this investigation. Sit‐to‐stand (STS) velocity and muscle power were calculated using the subject's body mass and height, chair height and the time needed to complete five STS repetitions, and compared with those obtained in the leg press exercise using a linear position transducer. In addition, STS performance, physical (gait speed) and cognitive function, sarcopenia (skeletal muscle index (SMI)) and health‐related quality of life (HRQoL) were recorded to assess the association with the STS muscle power values. Results: No significant differences were found between STS velocity and power values and those obtained from the leg press force‐velocity measurements (mean difference±95% CI=0.02±0.05m·s−1 and 6.9±29.8W, respectively) (both p>0.05). STS muscle power was strongly associated with maximal muscle power registered in the leg press exercise (r=0.72; p<0.001). In addition, cognitive function and SMI, and physical function, were better associated with absolute and relative STS muscle power, respectively, than STS time values after adjusting by different covariates. In contrast, STS time was slightly more associated with HRQoL than STS muscle power measures. Conclusion: The STS muscle power test proved to be a valid, and in general, a more clinically relevant tool to assess functional trajectory in older people compared to traditional STS time values. The low time, space and material requirements of the STS muscle power test, make this test an excellent choice for its application in large cohort studies and the clinical setting. HIGHLIGHTSSit‐to‐stand power was calculated from: sit‐to‐stand time, chair height, body mass and height.Sit‐to‐stand power was similar to that obtained from a validated instrument in the leg press exercise.Sit‐to‐stand power was independently associated with physical and cognitive function, sarcopenia and quality of life.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.exger.2018.08.006

Cites

53 of 53 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 53 references

Cited by

See all 355

Metadata

Authors
Alcazar, J., Losa-Reyna, J., Rodriguez-Lopez, C., Alfaro-Acha, A., Rodriguez-Mañas, L., Ara, I., García-García, F. J., & Alegre, L. M.
Venue
Experimental Gerontology
Publisher
Elsevier BV
Published
2018-10
Volume
112
Pages
38-43
ISSN
0531-5565 (ISSN-L)
OpenAlex
W2889106796
Cited by
355
References
53
FWCI
11.73
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The sit-to-stand muscle power test: An easy, inexpensive and portable procedure to assess muscle power in older people. https://app.cochat.ai/papers/10.1016/j.exger.2018.08.006
The paper
Alcazar, J., Losa-Reyna, J., Rodriguez-Lopez, C., Alfaro-Acha, A., Rodriguez-Mañas, L., Ara, I., García-García, F. J., & Alegre, L. M. (2018). The sit-to-stand muscle power test: An easy, inexpensive and portable procedure to assess muscle power in older people. Experimental Gerontology. https://doi.org/10.1016/j.exger.2018.08.006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.