Dynamic dip testing as a method to assess the condensate drainage behavior from the air-side surface of compact heat exchangers
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Water retention can alternatively be computed without experimental data from static mechanical or dynamic mechanical models.
“Alternatively, the water retention can be computed without experimental data from static mechanical [37] or dynamic mechanical [38] models with the developments of [39-41].”
From Model for cyclic frosting and defrosting of flat tube heat exchangers: Theoretical analysis and experimental validation (2023) · cites this paper as [37]
The model from Zhong et al. [37] diverges from the experimental results as the simulation continues, eventually reaching M_film,r ≈ 0 at t_drain = 230s.
“However, the model diverges from the experimental results as the simulation continues, eventually reaching 𝑀 f ilm , r ≈ 0 at 𝑡 drain = 230s.”
From Model for cyclic frosting and defrosting of flat tube heat exchangers: Theoretical analysis and experimental validation (2023) · cites this paper as [37]
The mass of water retained on the heat exchanger was different for dynamic dip testing and wind tunnel testing.
“However, the mass of water retained on the heat exchanger was different for both test methods.”
Both dynamic dip testing and wind tunnel testing yield the same condensate retention characteristics for different test samples.
“Both test methods yield the same condensate retention characteristics for different test samples.”
Dynamic dip testing could be used as a useful method to evaluate the condensate drainage characteristics of heat exchangers.
“Zhang et al. [76] claimed that dynamic dip testing could be used as a useful method to evaluate the condensate drainage characteristics of the heat exchangers.”
The difference in water retention could be a combined effect of the different fin geometry and the different construction of coil at the bottom.
“The difference in water retention could be a combined effect of the different fin geometry (see McLaughlin and Webb [22]) and the different construction of coil at the bottom (see Zhong et al. [23]).”
From Frost, defrost, and refrost and its impact on the air-side thermal-hydraulic performance of louvered-fin, flat-tube heat exchangers (2006) · cites this paper as Zhong et al. [23]
Dynamic dip testing provides highly repeatable data for real-time drainage of compact heat exchangers.
“The new method provides highly repeatable data for real-time drainage.”
Cited by
Sorted by citations
Xia, Y., Zhong, Y., Hrnjak, P. S., & Jacobi, A. M. (2006) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2006.03.005 · Cited by 148 · see citing works
Self-citationPatil, M. S., Seo, J.-H., & Lee, M.-Y. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.11.107 · Cited by 86 · see citing works
Zhang, P., & Hrnjak, P. S. (2009) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2008.11.006 · Cited by 75 · see citing works
Li, F., Wu, S., Ma, Z., Zhao, R., & Huang, D. (2022) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.118220 · Cited by 36 · see citing works
Xiong, T., Liu, G., Gao, Q., Yan, G., & Yu, J. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105654 · Cited by 26 · see citing works
Flat tube heat exchangers: Experimental analysis of frosting and water retention
Westhaeuser, J., Brauchle, L., Albrecht, J.-C., Tegethoff, W., Lemke, N., & Koehler, J. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.119319 · Cited by 24 · see citing works
Westhaeuser, J., Schulze, C., Albrecht, J.-C., Tegethoff, W., Lemke, N., & Koehler, J. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.120140 · Cited by 12 · see citing works
- Authors
- Zhong, Y., Joardar, A., Gu, Z., Park, Y.-G., & Jacobi, A. M.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- Corresponding author
- Zhong, Yongfang
- ORCID
- Jacobi, Anthony M.
- Venue
- Experimental Thermal and Fluid Science
- Publisher
- Elsevier BV
- Published
- 2005-09
- Volume
- 29
- Issue
- 8
- Pages
- 957-970
- ISSN
- 0894-1777 (ISSN-L)
- OpenAlex
- W1993988952
- Cited by
- 37
- References
- 0
- Citations by year
- 2024: 2 · 2023: 3 · 2022: 3 · 2020: 2 · 2019: 2 · 2018: 3 · 2017: 2 · 2016: 1 · 2014: 2 · 2013: 4 · 2012: 5
- FWCI
- 3.33
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Experimental Thermal and Fluid Science (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Boiling Studies
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Keywords
- condensate drainage, compact heat exchangers, flat tube heat exchanger, finned tube heat exchanger, wind tunnel testing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review