Deep eutectic solvent (DES) with silver nanoparticles (Ag-NPs) based assay for analysis of lead (II) in edible oils
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
This paper presents an application of silver nanoparticles impregnated by Deep Eutectic Solvents (DES) as ultrasonication aided microextraction system for lead (II) determination in edible oils. The paper presents a systematic optimization of method parameters and examples of its application for analysis of real samples. Maximum recovery for lead (II) extraction was obtained for choline chloride and phenol with a 1:2 M ratio. Optimum extraction conditions for 2 g oil sample post-digested solution (10 mL, pH = 2) require 1 mL of Ag-nanoparticles solution (0,1mM) and per each 500 µL of DES and tetrahydrofurane. The limit of detection (LOD) and quantification (LOQ) were 0.28 µg/L and 0.94 µg/L. The developed method covers the entire range of expected levels of lead concentration in oil samples -parts per billion levels to higher ones. This method is many folds faster (only 6.5 min/sample are needed) as well as more sensitive comparing to already reported methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lead Uptake, Toxicity, and Detoxification in Plants
Pourrut, B., Shahid, M., Dumat, C., Winterton, P., & Pinelli, E. (2011) · Reviews of Environmental Contamination and Toxicology · doi:10.1007/978-1-4419-9860-6_4 · Cited by 937
Makoś, P., Przyjazny, A., & Boczkaj, G. (2018) · Journal of Chromatography A · doi:10.1016/j.chroma.2018.07.070 · Cited by 342
Self-citationRecent Advances in Hydrophobic Deep Eutectic Solvents for Extraction
Dwamena, A. (2019) · Separations · doi:10.3390/separations6010009 · Cited by 294
Fernandes, A., Makoś, P., Khan, J. A., & Boczkaj, G. (2019) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2018.10.081 · Cited by 185
Self-citationKhezeli, T., Daneshfar, A., & Sahraei, R. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.11.007 · Cited by 183
Karimi, M., Shabani, A. M. H., & Dadfarnia, S. (2016) · Microchimica Acta · doi:10.1007/s00604-015-1671-9 · Cited by 94
Cited by
Physicochemical properties of deep eutectic solvents: A review
Omar, K. A., & Sadeghi, R. (2022) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2022.119524 · Cited by 521
Heavy Metals in Foods and Beverages: Global Situation, Health Risks and Reduction Methods
Scutarașu, E. C., & Trincă, L. C. (2023) · Foods · doi:10.3390/foods12183340 · Cited by 179
Deep eutectic solvents: Preparation, properties, and food applications
Negi, T., Kumar, A., Sharma, S. K., Rawat, N., Saini, D., Sirohi, R., Prakash, O., Dubey, A., Dutta, A., & Shahi, N. C. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e28784 · Cited by 179
“Ul Haq, Bibi, Balal Arain, Safi, Ullah, Castro-Mu ˜ noz and Boczkaj [176] discovered new method for the determination of lead (II) ions from various commercial edible oil products.”
BackgroundMarchel, M., Rayaroth, M. P., Wang, C., Kong, L., Khan, J. A., & Boczkaj, G. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2023.144971 · Cited by 135
Self-citationCastro-Muñoz, R., Can Karaça, A., Saeed Kharazmi, M., Boczkaj, G., Hernández-Pinto, F. J., Anusha Siddiqui, S., & Jafari, S. M. (2024) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2023.2230500 · Cited by 54
Self-citation
Metadata
- Authors
- Ul Haq, H., Bibi, R., Balal Arain, M., Safi, F., Ullah, S., Castro-Muñoz, R., & Boczkaj, G.
- Venue
- Food Chemistry
- Publisher
- Elsevier BV
- Published
- 2022-06
- Volume
- 379
- Pages
- 132085
- ISSN
- 0308-8146 (ISSN-L)
- OpenAlex
- W4205846550
- Cited by
- 91
- References
- 6
- FWCI
- 9.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.