Electronic tongue and electronic nose for food quality and safety
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
For the needs of food producers and consumers, electronic tongue and electronic nose play many roles for food quality and safety in food production, food supervision and daily life. The principles and progresses of electronic tongue and electronic nose were elaborated. The core hardware namely electronic tongue sensors and electronic nose sensors, and the core software namely intelligent sensory algorithms were summarized. It was found that the proportion of electronic tongue and electronic nose employed in food quality control and monitoring in production was the highest. Electronic tongue and electronic nose with the prediction accuracy of 80-96 % accounted for a large proportion in the applications of food. The superposition operation of two or more intelligent sensory algorithms has become routine. In addition, the combination of electronic tongue and electronic nose was highlighted. It was resulted that the ability of food category recognition and quality prediction of the combined technology of electronic nose and electronic tongue showed an increase of 8-25 % compared with the single technology. The future challenges and expectations of electronic tongue and electronic nose were discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Partial least squares for discrimination
Barker, M., & Rayens, W. (2003) · Journal of Chemometrics · doi:10.1002/cem.785 · Cited by 2,841
A brief history of electronic noses
Gardner, J. W., & Bartlett, P. N. (1994) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(94)87085-3 · Cited by 1,255
Deep learning for healthcare applications based on physiological signals: A review
Faust, O., Hagiwara, Y., Hong, T. J., Lih, O. S., & Acharya, U. R. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.04.005 · Cited by 1,026
Vlasov, Y., Legin, A., Rudnitskaya, A., Di Natale, C., & D'Amico, A. (2005) · Pure and Applied Chemistry · doi:10.1351/pac200577111965 · Cited by 423
The structural basis of odorant recognition in insect olfactory receptors
del Mármol, J., Yedlin, M. A., & Ruta, V. (2021) · Nature · doi:10.1038/s41586-021-03794-8 · Cited by 302
Recent advances in electronic tongues
Riul Jr., A., Dantas, C. A. R., Miyazaki, C. M., & Oliveira Jr., O. N. (2010) · The Analyst · doi:10.1039/c0an00292e · Cited by 284
Food Safety, Food Fraud, and Food Defense: A Fast Evolving Literature
Manning, L., & Soon, J. M. (2016) · Journal of Food Science · doi:10.1111/1750-3841.13256 · Cited by 268
The Stability and Shelf-life of Food
(2000) · doi:10.1201/9781439822869 · Cited by 235
Azarmdel, H., Jahanbakhshi, A., Mohtasebi, S. S., & Rosado-Muñoz, A. (2020) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2020.111201 · Cited by 209
Horse meat scandal – A wake-up call for regulatory authorities
Premanandh, J. (2013) · Food Control · doi:10.1016/j.foodcont.2013.05.033 · Cited by 208
Wine classification by taste sensors made from ultra-thin films and using neural networks
Riul, A., de Sousa, H. C., Malmegrim, R. R., dos Santos, D. S., Carvalho, A. C. P. L. F., Fonseca, F. J., Oliveira, O. N., & Mattoso, L. H. C. (2004) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2003.09.025 · Cited by 186
The melamine adulteration scandal
Sharma, K., & Paradakar, M. (2010) · Food Security · doi:10.1007/s12571-009-0048-5 · Cited by 169
An artificial taste sensor based on conducting polymers
Riul, A., Malmegrim, R. R., Fonseca, F. J., & Mattoso, L. H. C. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00069-1 · Cited by 161
Benedetti, S., Buratti, S., Spinardi, A., Mannino, S., & Mignani, I. (2007) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2007.06.012 · Cited by 158
DWTLSTM for electronic nose signal processing in beef quality monitoring
Wijaya, D. R., Sarno, R., & Zulaika, E. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.128931 · Cited by 155
Portable Electronic Nose Based on Electrochemical Sensors for Food Quality Assessment
Wojnowski, W., Majchrzak, T., Dymerski, T., Gębicki, J., & Namieśnik, J. (2017) · Sensors · doi:10.3390/s17122715 · Cited by 154
Calvini, R., & Pigani, L. (2022) · Sensors · doi:10.3390/s22020577 · Cited by 137
The combination of an electronic tongue and an electronic nose
Winquist, F., Lundström, I., & Wide, P. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00155-0 · Cited by 133
Cho, Y. H., Ko, Y. N., Kang, Y. C., Kim, I., & Lee, J. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.01.021 · Cited by 127
Amperometric electronic tongue for food analysis
Scampicchio, M., Ballabio, D., Arecchi, A., Cosio, M. S., & Mannino, S. (2008) · Microchimica Acta · doi:10.1007/s00604-008-0915-8 · Cited by 118
Hareesha, N., Manjunatha, J. G., Amrutha, B. M., Sreeharsha, N., Asdaq, S. M. B., & Anwer, M. K. (2021) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2021.127042 · Cited by 117
Gancarz, M., Dobrzański, B., Jr., Oniszczuk, T., Combrzyński, M., Ćwikła, D., & Rusinek, R. (2020) · Sensors · doi:10.3390/s20072124 · Cited by 115
Limbo, S., Sinelli, N., Torri, L., & Riva, M. (2009) · LWT · doi:10.1016/j.lwt.2008.12.011 · Cited by 109
Shelf life evaluation of fresh-cut pineapple by using an electronic nose
Torri, L., Sinelli, N., & Limbo, S. (2010) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2010.01.012 · Cited by 103
AN ELECTRONIC ANALOG FOR THE OLFACTORY PROCESSES*†
Wilkens, W. F., & Hartman, J. D. (1964) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1964.tb45092.x · Cited by 91
Yang, Z., Miao, N., Zhang, X., Li, Q., Wang, Z., Li, C., Sun, X., & Lan, Y. (2020) · Food Control · doi:10.1016/j.foodcont.2020.107608 · Cited by 89
Gancarz, M., Dobrzański, B., Jr., Malaga-Toboła, U., Tabor, S., Combrzyński, M., Ćwikła, D., Strobel, W., Oniszczuk, A., Karami, H., Darvishi, Y., et al. (2022) · Molecules · doi:10.3390/molecules27051559 · Cited by 65
Han, F., Huang, X., & Teye, E. (2018) · Journal of Food Process Engineering · doi:10.1111/jfpe.12983 · Cited by 60
Application of electronic tongues in food processing
Wadehra, A., & Patil, P. (2015) · Analytical Methods · doi:10.1039/c5ay02724a · Cited by 57
Poultry meat freshness evaluation using electronic nose technology and ultra-fast gas chromatography
Wojnowski, W., Majchrzak, T., Dymerski, T., Gębicki, J., & Namieśnik, J. (2017) · Monatshefte für Chemie - Chemical Monthly · doi:10.1007/s00706-017-1969-x · Cited by 49
Will China lead the world in AI by 2030?
O’Meara, S. (2019) · Nature · doi:10.1038/d41586-019-02360-7 · Cited by 47
Random subspace method for analysing coffee with electronic tongue
Ferreira, E. J., Pereira, R. C. T., Delbem, A. C. B., Oliveira, O. N., & Mattoso, L. H. C. (2007) · Electronics Letters · doi:10.1049/el:20071182 · Cited by 43
Kalinke, C., de Oliveira, P. R., Bonet‐San‐Emeterio, M., González‐Calabuig, A., del Valle, M., Mangrich, A. S., Junior, L. H. M., & Bergamini, M. F. (2019) · Electroanalysis · doi:10.1002/elan.201900072 · Cited by 40
Cuprous Oxide Based Chemiresistive Electronic Nose for Discrimination of Volatile Organic Compounds
Liu, B., Wu, X. M., Kam, K. W. L., Cheung, W., & Zheng, B. (2019) · ACS Sensors · doi:10.1021/acssensors.9b01697 · Cited by 32
Misaghpour, F., & Shabani‐Nooshabadi, M. (2017) · Food Analytical Methods · doi:10.1007/s12161-017-1035-7 · Cited by 30
Dai, C., Huang, X., Huang, D., Lv, R., Sun, J., Zhang, Z., Ma, M., & Aheto, J. H. (2019) · Journal of Food Process Engineering · doi:10.1111/jfpe.13002 · Cited by 30
Facure, M., Schneider, R., dos Santos, D. M., & Corrêa, D. (2020) · Talanta: The International Journal of Pure and Applied Analytical Chemistry · doi:10.1016/j.talanta.2020.121039 · Cited by 30
Lu, L., Hu, Z., Hu, X., Han, J., Zhu, Z., Tian, S., & Chen, Z. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.129254 · Cited by 26
Self-citationA fluorescent sensor array-based electronic tongue for Chinese tea discrimination
Zhu, Y., Wang, J., Wu, Y., Shang, Z., Ding, Y., & Hu, A. (2021) · Journal of Materials Chemistry C · doi:10.1039/d1tc00491c · Cited by 23
Detection of Volatiles in Dark Chocolate Flavored with Orange Essential Oil by Electronic Nose
Galvagni, E., Fritzen, A. A., Graboski, A. M., Ballen, S. C., Steffens, J., & Steffens, C. (2020) · Food Analytical Methods · doi:10.1007/s12161-020-01763-x · Cited by 17
Xie, D., Peng, W., Chen, J.-C., Li, L., Zhao, C., Yang, S.-L., Xu, M. H., Wu, C., & Ai, L. (2016) · Food Science and Biotechnology · doi:10.1007/s10068-016-0239-8 · Cited by 15
Cited by
Porous materials as effective chemiresistive gas sensors
Sharma, A., Eadi, S. B., Noothalapati, H., Otyepka, M., Lee, H.-D., & Jayaramulu, K. (2024) · Chemical Society Reviews · doi:10.1039/d2cs00761d · Cited by 352
Mei, H., Peng, J., Wang, T., Zhou, T., Zhao, H., Zhang, T., & Yang, Z. (2024) · Nano-Micro Letters · doi:10.1007/s40820-024-01489-z · Cited by 177
Deep learning in food authenticity: Recent advances and future trends
Deng, Z., Wang, T., Zheng, Y., Zhang, W., & Yun, Y.-H. (2024) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2024.104344 · Cited by 173
Hua, Q., Ma, Q., Yi, H., Zhang, L., Liang, X., & Zhang, Z. (2026) · Food Chemistry · doi:10.1016/j.foodchem.2026.150594 · Cited by 1
Metadata
- Authors
- Lu, L., Hu, Z., Hu, X., Li, D., & Tian, S.
- Venue
- Food Research International
- Publisher
- Elsevier BV
- Published
- 2022-12
- Volume
- 162
- Issue
- Pt B
- Pages
- 112214
- ISSN
- 0963-9969 (ISSN-L)
- OpenAlex
- W4309769934
- Cited by
- 306
- References
- 41
- FWCI
- 14.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.