The DOI matches its Crossref record.
Demonstrating full-scale post-combustion CO2 capture for coal-fired power plants through dynamic modelling and simulation
Open accessAbstract
This study aims to provide insights into the design and operation of full-scale post-combustion CO 2 capture for a 500 MWe sub-critical power plant through dynamic modelling and simulation. The development and validation of the dynamic models of the power plant and CO 2 capture plant are described. In addition, the scale-up of the CO 2 capture plant from pilot plant scale (where it was validated) to full scale is discussed. Subsequently the manner in which the two plant models were linked is discussed. A floating IP/LP crossover pressure configuration is used. A throttling valve is included between the LP turbine and draw-off point to prevent pressures at the crossover from dropping below required levels in the reboiler for solvent regeneration. The flue gas from the power plant is treated before it is sent to the CO 2 capture plant. Four case studies are considered. The first investigates the effect of increasing solvent concentration on the performance of the power plant with the capture plant. The second investigates which absorber packing height offers a good balance between capital and operating costs. The two dynamic case studies show that the CO 2 capture plant has a slower response than the power plant. They also reveal an interaction of CO 2 capture level and power plant output control loops making it difficult to achieve steady power output levels quickly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Post-combustion CO2 capture with chemical absorption: A state-of-the-art review
Wang, M., Lawal, A., Stephenson, P., Sidders, J., & Ramshaw, C. (2011) · Chemical Engineering Research and Design · doi:10.1016/j.cherd.2010.11.005 · Cited by 1,458
Self-citationProcess intensification for post-combustion CO2 capture with chemical absorption: A critical review
Wang, M., Joel, A. S., Ramshaw, C., Eimer, D., & Musa, N. M. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.08.083 · Cited by 430
Self-citationOko, E., Zacchello, B., Wang, M., & Fethi, A. (2018) · Greenhouse Gases Science and Technology · doi:10.1002/ghg.1772 · Cited by 31
Self-citation
Metadata
- Authors
- Lawal, A., Wang, M., Stephenson, P., & Obi, O.
- Venue
- Fuel
- Publisher
- Elsevier BV
- Published
- 2012-11
- Volume
- 101
- Pages
- 115-128
- ISSN
- 0016-2361 (ISSN-L)
- OpenAlex
- W2048598854
- Cited by
- 202
- References
- 0
- FWCI
- 17.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Demonstrating full-scale post-combustion CO2 capture for coal-fired power plants through dynamic modelling and simulation. https://app.cochat.ai/papers/10.1016/j.fuel.2010.10.056
- The paper
- Lawal, A., Wang, M., Stephenson, P., & Obi, O. (2012). Demonstrating full-scale post-combustion CO2 capture for coal-fired power plants through dynamic modelling and simulation. Fuel. https://doi.org/10.1016/j.fuel.2010.10.056
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.