Cited by 79High-Temperature Coating BehaviorsThermochemical Biomass Conversion ProcessesChemical Looping and Thermochemical Processes

Reducing high-temperature corrosion on high-alloyed stainless steel superheaters by co-combustion of municipal sewage sludge in a fluidised bed boiler

Open access
Karlsson, Sofia, Åmand, Lars-Erik, Liske, Jesper·2015·Fuel

Abstract

One way of mitigating alkali chloride induced corrosion in biomass and waste-fired boilers is by using additives or by co-combustion and thereby decreasing the corrosiveness of the flue gas and deposits. The effect of co-firing digested sewage sludge with a mixture of biomass and waste (78% bark pellets + 22% Solid Recovered Fuel, denoted “SRF”) was investigated in a 12 MW circulating fluidised bed (CFB) boiler. The initial corrosion attack of the stainless steel 304L at 600 °C (material temperature) was investigated during 24 h exposures. The exposures were carried out in the flue gas environment from three fuel-mixes: SRF, MSS1-low (SRF with municipal sewage sludge, low dosage) and MSS2-high (SRF with municipal sewage sludge, high dosage). The results showed that the most severe corrosion attack on 304L occurred without sewage sludge in the SRF exposure. This attack was characterised by a corrosion product layer up to 100 μm in thickness and signs of internal corrosion of the steel. The deposit in the SRF case was dominated by alkali chlorides. The exposures with co-combustion of sewage sludge, MSS1-low and MSS2-high, showed a significant decrease in corrosion. The steel sample of 304L performed especially well in the latter case when it was protected by a thin oxide of less than 0.3 μm in thickness. This deposit was dominated by sulphate- and phosphate-containing compounds but traces of aluminium silicate compounds where also found. Furthermore, the concentration of alkali chlorides was low. Thus, the initial corrosion attack was greatly reduced by co-combustion of digested sewage sludge with SRF.

Integrity signals

Registry

Crossref · 10.1016/j.fuel.2014.09.007

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 42 · Cited by 79

Authors
Karlsson, S., Åmand, L.-E., & Liske, J.
Affiliations
Chalmers University of Technology (SE)
Corresponding author
Karlsson, Sofia
Venue
Fuel
Publisher
Elsevier BV
Published
2015-01
Volume
139
Pages
482-493
ISSN
0016-2361 (ISSN-L)
OpenAlex
W2110954960
Cited by
79
References
42
Citations by year
2026: 3 · 2025: 2 · 2024: 8 · 2023: 8 · 2022: 5 · 2021: 5 · 2020: 12 · 2019: 4 · 2018: 9 · 2017: 8 · 2016: 7 · 2015: 8
FWCI
11.31
Type
journal article
Language
en
Open access
Locations
  • Fuel (publishedVersion, cc-by-nc-nd)
  • Chalmers Publication Library (Chalmers University of Technology) (submittedVersion)
  • Chalmers Research (Chalmers University of Technology) (submittedVersion)
Funders
Chalmers Tekniska Högskola
Topics
  • Physical Sciences › Engineering › Aerospace Engineering › High-Temperature Coating Behaviors
  • Physical Sciences › Engineering › Biomedical Engineering › Thermochemical Biomass Conversion Processes
  • Physical Sciences › Engineering › Biomedical Engineering › Chemical Looping and Thermochemical Processes
Keywords
high-temperature corrosion, sewage sludge, co-combustion, circulating fluidized bed boiler, 304L stainless steel, solid recovered fuel, biomass co-firing, corrosion product layer

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›