Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 161

The DOI matches its Crossref record.

Predicting lower limb joint kinematics using wearable motion sensors

Open access
Findlow, A., Goulermas, J.Y., Nester, C., Howard, D., Kenney, L.P.J. · 2008 · Gait & Posture

Abstract

The aim of this study was to estimate sagittal plane ankle, knee and hip gait kinematics using 3D angular velocity and linear acceleration data from motion sensors on the foot and shank. We explored the accuracy of intra-subject predictions (i.e., where training and testing uses trials from the same subject) and inter-subject (where testing uses subjects different from the ones used for training) predictions, and the effect of loss of sensor data on prediction accuracy. Hip, knee and ankle kinematic data were collected using reflective markers. Simultaneously, foot and shank angular velocity and linear acceleration data were collected using small integrated accelerometers/gyroscope units. A generalised regression networks algorithm was used to predict the former from the latter. The best results were from intra-subject predictions, with very high correlations (0.93-0.99) and low mean absolute deviation (< or =2.3 degrees ) between measured kinematic joint angles and predicted angles. The inter-subject case produced poorer correlations (0.70-0.89) and larger absolute differences between measured and predicted angles, ranging from 4.91 degrees (left ankle) to 9.06 degrees (right hip). The angular velocity data added little to the accuracy of predictions and there was also minimal benefit to using sensor data from the shank. Thus, a wearable system based only on footwear mounted sensors and a simpler sensor set providing only acceleration data shows potential. Whilst predictions were generally stable when sensor data was lost, it remains to be seen whether the generalised regression networks algorithm is robust for other activities such as stair climbing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.gaitpost.2007.11.001

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 161

Metadata

Authors
Findlow, A., Goulermas, J. Y., Nester, C., Howard, D., & Kenney, L. P. J.
Venue
Gait & Posture
Publisher
Elsevier BV
Published
2008-07
Volume
28
Issue
1
Pages
120-126
ISSN
0966-6362 (ISSN-L)
OpenAlex
W2005641898
Cited by
161
References
0
FWCI
14.80
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Predicting lower limb joint kinematics using wearable motion sensors. https://app.cochat.ai/papers/10.1016/j.gaitpost.2007.11.001
The paper
Findlow, A., Goulermas, J. Y., Nester, C., Howard, D., & Kenney, L. P. J. (2008). Predicting lower limb joint kinematics using wearable motion sensors. Gait & Posture. https://doi.org/10.1016/j.gaitpost.2007.11.001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.