A comparison of accelerometry and center of pressure measures during computerized dynamic posturography: A measure of balance

Open access
Whitney, S.L., Roche, J.L., Marchetti, G.F., Lin, C.-C., Steed, D.P., Furman, G.R., Musolino, M.C., Redfern, M.S.·2011·Gait & Posture

Abstract

Accelerometry (ACC) shows promise as an easily implemented clinical measure of balance. The purpose of the study was to estimate test–retest reliability of ACC measures and determine the relationship between ACC measured at the pelvis and underfoot center of pressure (COP) measures during sensory organization test (SOT) conditions. Eighty-one subjects were recruited from the community with no known orthopedic or vestibular deficits (19–85 years). Subjects completed three consecutive, ninety second trials for each of the six SOT conditions, while wearing the accelerometer. ACC and COP time series were described by calculating the normalized path length, root mean square (RMS), and peak-to-peak values. The test–retest reliability of the three measures within each SOT condition was estimated over three trials using the intraclass correlation coefficient. ACC and COP test–retest reliability were similar, ranging from 0.63 to 0.80 using ACC and 0.42 to 0.81 using COP for the measure of normalized path length. Linear regression between ACC and COP measures showed significant correlation under almost every SOT condition using both single and average measures across trials. The degree of association between COP and ACC was equivalent when using the first trial or the 3-trial average, suggesting that one trial may be sufficient. The use of accelerometry may have value in estimating balance function and minimizing clinical evaluation time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.gaitpost.2011.01.015

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 186

Metadata

Authors
Whitney, S. L., Roche, J. L., Marchetti, G. F., Lin, C.-C., Steed, D. P., Furman, G. R., Musolino, M. C., & Redfern, M. S.
Venue
Gait & Posture
Publisher
Elsevier BV
Published
2011-04
Volume
33
Issue
4
Pages
594-599
ISSN
0966-6362 (ISSN-L)
OpenAlex
W1996845679
Cited by
186
References
1
FWCI
20.52
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A comparison of accelerometry and center of pressure measures during computerized dynamic posturography: A measure of balance. https://app.cochat.ai/papers/10.1016/j.gaitpost.2011.01.015
The paper
Whitney, S. L., Roche, J. L., Marchetti, G. F., Lin, C.-C., Steed, D. P., Furman, G. R., Musolino, M. C., & Redfern, M. S. (2011). A comparison of accelerometry and center of pressure measures during computerized dynamic posturography: A measure of balance. Gait & Posture. https://doi.org/10.1016/j.gaitpost.2011.01.015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.