Differential effects of fatigue on movement variability
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
When individuals perform purposeful actions to fatigue, there is typically a general decline in their movement performance. This study was designed to investigate the effects exercise-induced fatigue has on lower limb kinetics and kinematics during a side-step cutting task. In particular, it was of interest to determine what changes could be seen in mean amplitude and all metrics of signal variability with fatigue. The results of the study revealed that post-fatigue there was an overall decrease in absolute force production as reflected by a decline in mean amplitude and variability (SD) of the ground reaction forces (GRFV and GRFML). A decrease in mean and SD of the knee moments were also observed post-exercise. Interestingly, this trend was not mirrored by similar changes in time-dependent properties of these signals. Instead, there was an increase in the SampEn values (reflecting a more variable, irregular signal) for GRF force profiles, knee kinematics and moments following the exercise-induced fatigue. These results illustrate that fatigue can have differential effects on movement variability, resulting in a both an increase and decrease in movement variability, depending on the variable selected. Thus, the impact of fatigue is not simply restricted to a decline in force producing capacity of the system but more importantly it demonstrates that the ability of the person to perform a smooth and controlled action is limited due to fatigue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiological time-series analysis using approximate entropy and sample entropy
Richman, J. S., & Moorman, J. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.6.h2039 · Cited by 7,880 · cited 1×
“This analysis determines the conditional probability of the signal by providing a measure of the (logarithmic) likelihood that runs of patterns that are close for m observations (epochs) remain close for incremental (m + 1) comparisons [9,10].”
Cited by
Li, Y., Mache, M. A., & Todd, T. A. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2020.110073 · Cited by 29
Pettinato, F., Valle, M. S., Cioni, M., Cirnigliaro, L., Rizzo, R., Barone, R., Bosco, G., & Casabona, A. (2024) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-024-01520-9 · Cited by 9
Alfaro-Magallanes, V., Benito, P., Rael, B., Barba-Moreno, L., Romero-Parra, N., Cupeiro, R., Swinkels, D., Laarakkers, C., Peinado, A., & on behalf of the IronFEMME Study Group (2020) · Nutrients · doi:10.3390/nu12123866 · Cited by 5
“VO2 measurements in the incremental test to exhaustion, as previously reported [42].”
Method
Metadata
- Authors
- Cortes, N., Onate, J., & Morrison, S.
- Venue
- Gait & Posture
- Publisher
- Elsevier BV
- Published
- 2014-03
- Volume
- 39
- Issue
- 3
- Pages
- 888-893
- ISSN
- 0966-6362 (ISSN-L)
- OpenAlex
- W2000710952
- Cited by
- 120
- References
- 1
- FWCI
- 1.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Differential effects of fatigue on movement variability. https://app.cochat.ai/papers/10.1016/j.gaitpost.2013.11.020
- The paper
- Cortes, N., Onate, J., & Morrison, S. (2014). Differential effects of fatigue on movement variability. Gait & Posture. https://doi.org/10.1016/j.gaitpost.2013.11.020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.