Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 188

The DOI matches its Crossref record.

Analysis of the performance of 17 algorithms from a systematic review: Influence of sensor position, analysed variable and computational approach in gait timing estimation from IMU measurements

Pacini Panebianco, Giulia, Bisi, Maria Cristina, Stagni, Rita, Fantozzi, Silvia · 2018 · Gait & Posture

Abstract

BACKGROUND The quantification of gait temporal parameters (i.e. step time, stance time) is crucial in human motion analysis and requires the accurate identification of gait events (i.e. heel strike, toe off). With the widespread use of inertial wearable sensors, many algorithms were proposed and applied for the purpose. Nevertheless, only few studies addressed the assessment of the actual performance of these algorithms, rather considering each proposed algorithm as a whole. RESEARCH QUESTION How different implementation characteristics influence the assessment of gait events and temporal parameters from inertial sensor measures in terms of accuracy and repeatability? METHODS Seventeen different algorithms were identified from a systematic review and classified based on: 1) sensor position, 2) target variable, 3) computational approach. The influence of these characteristics was analysed on walking data of 35 healthy volunteers mounting 5 tri-axial inertial sensors. Foot contact events identified by 2 force platforms were assumed as gold standard. Temporal parameters were calculated from gait events. Algorithm performance was analysed in terms of accuracy (error median value) and repeatability (error 25th and 75th percentile values). RESULTS Shank- and foot-based algorithms performed better (in terms of accuracy and repeatability) in gait events detection and stance time estimation than lower trunk-based ones, while sensor position did not affect step estimate, given the error bias characteristics. Angular velocity-based algorithms performed significantly better than acceleration-based ones for toe off detection in terms of repeatability (68 ms and 102 ms, 25th-75th percentile error range, respectively) and, for heel strike detection, showed better repeatability (40 ms and 111 ms) and comparable accuracy (65 ms and 60 ms median error, respectively) than acceleration-based ones. The performance of different computational approaches varied depending on sensor positioning. SIGNIFICANCE Present results support the selection of the proper algorithm for the estimation of gait events and temporal parameters in relation to the specific application.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.gaitpost.2018.08.025

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 188

Metadata

Authors
Pacini Panebianco, G., Bisi, M. C., Stagni, R., & Fantozzi, S.
Venue
Gait & Posture
Publisher
Elsevier BV
Published
2018-10
Volume
66
Pages
76-82
ISSN
0966-6362 (ISSN-L)
OpenAlex
W2888531427
Cited by
188
References
0
FWCI
1.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analysis of the performance of 17 algorithms from a systematic review: Influence of sensor position, analysed variable and computational approach in gait timing estimation from IMU measurements. https://app.cochat.ai/papers/10.1016/j.gaitpost.2018.08.025
The paper
Pacini Panebianco, G., Bisi, M. C., Stagni, R., & Fantozzi, S. (2018). Analysis of the performance of 17 algorithms from a systematic review: Influence of sensor position, analysed variable and computational approach in gait timing estimation from IMU measurements. Gait & Posture. https://doi.org/10.1016/j.gaitpost.2018.08.025

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.