The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Optimization of IMU Sensor Placement for the Measurement of Lower Limb Joint Kinematics
Open accessAbstract
There is an increased interest in using wearable inertial measurement units (IMUs) in clinical contexts for the diagnosis and rehabilitation of gait pathologies. Despite this interest, there is a lack of research regarding optimal sensor placement when measuring joint kinematics and few studies which examine functionally relevant motions other than straight level walking. The goal of this clinical measurement research study was to investigate how the location of IMU sensors on the lower body impact the accuracy of IMU-based hip, knee, and ankle angular kinematics. IMUs were placed on 11 different locations on the body to measure lower limb joint angles in seven participants performing the timed-up-and-go (TUG) test. Angles were determined using different combinations of IMUs and the TUG was segmented into different functional movements. Mean bias and root mean square error values were computed using generalized estimating equations comparing IMU-derived angles to a reference optical motion capture system. Bias and RMSE values vary with the sensor position. This effect is partially dependent on the functional movement analyzed and the joint angle measured. However, certain combinations of sensors produce lower bias and RMSE more often than others. The data presented here can inform clinicians and researchers of placement of IMUs on the body that will produce lower error when measuring joint kinematics for multiple functionally relevant motions. Optimization of IMU-based kinematic measurements is important because of increased interest in the use of IMUs to inform diagnose and rehabilitation in clinical settings and at home.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The first is methodological heterogeneity in sensor placement, feature extraction, and analysis pipelines across studies, compounded by the absence of task-optimized sensor configurations (Prasanth et al., 2021; Niswander et al., 2020).”
From Multimodal neuroimaging and AI integration in cognitive disorders: advances, challenges, and future directions for precision medicine (2026) · cites this paper as Niswander et al., 2020
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Muro-de-la-Herran, A., Garcia-Zapirain, B., & Mendez-Zorrilla, A. (2014) · Sensors · doi:10.3390/s140203362 · Cited by 1,172 · cited 1×
“While direct observation of human gait is easily done, the quantification of gait is more difficult but important to effectively track changes over time or compare gait to other clinical populations [2].”
BackgroundDeterminants of the Sit-to-Stand Movement: A Review
Janssen, W. G., Bussmann, H. B., & Stam, H. J. (2002) · Physical Therapy · doi:10.1093/ptj/82.9.866 · Cited by 692 · cited 1×
“Examining functional movements such as sit-to-stand and turning are important to clinicians because they aid in assessing lower extremity strength and balance [8,9].”
BackgroundInertial Sensor-Based Stride Parameter Calculation From Gait Sequences in Geriatric Patients
Rampp, A., Barth, J., Schuelein, S., Gassmann, K.-G., Klucken, J., & Eskofier, B. M. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2368211 · Cited by 303 · cited 1×
“Heel 5 Kwakkel 2007 [17], Anwary 2018 [11], Khan 2017 [32], Lau 2008 [33], Rebula 2013 [34] Lateral, below lateral malleolus 3 Anwary 2018 [11], Rampp 2014 [35], Reinfelder 2015 [4]”
Spain, R. I., St. George, R. J., Salarian, A., Mancini, M., Wagner, J. M., Horak, F. B., & Bourdette, D. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2011.11.026 · Cited by 287
Picerno, P. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2016.11.008 · Cited by 237
Gait posture estimation using wearable acceleration and gyro sensors
Takeda, R., Tadano, S., Natorigawa, A., Todoh, M., & Yoshinari, S. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.07.016 · Cited by 197 · cited 1×
“Other studies have reported lower RMSE values at the same joints [39,40].”
BackgroundPacini Panebianco, G., Bisi, M. C., Stagni, R., & Fantozzi, S. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2018.08.025 · Cited by 188 · cited 4×
“A few publications optimized sensor placement when measuring gait parameters such as stance/swing percent and cadence [10,11] and evaluated sensitivity of pose estimation accuracy to IMU sensor placements during single leg squats [12].”
BackgroundInfluentialPalermo, E., Rossi, S., Marini, F., Patanè, F., & Cappa, P. (2014) · Measurement · doi:10.1016/j.measurement.2014.03.004 · Cited by 182 · cited 1×
“was used to define calibration vectors describing body segment orientations in terms of sensor coordinate systems and is briefly described here [18].”
MethodMeasurement of foot placement and its variability with inertial sensors
Rebula, J. R., Ojeda, L. V., Adamczyk, P. G., & Kuo, A. D. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.05.012 · Cited by 180 · cited 1×
“Heel 5 Kwakkel 2007 [17], Anwary 2018 [11], Khan 2017 [32], Lau 2008 [33], Rebula 2013 [34] Lateral, below lateral malleolus 3 Anwary 2018 [11], Rampp 2014 [35], Reinfelder 2015 [4]”
Clinimetric Properties of the Timed Up and Go Test for Patients With Stroke: A Systematic Review
Hafsteinsdóttir, T. B., Rensink, M., & Schuurmans, M. (2014) · Topics in Stroke Rehabilitation · doi:10.1310/tsr2103-197 · Cited by 176 · cited 1×
“Participants performed the Timed-Up-And-Go (TUG) test given its extensive validation in clinical populations and the variety of functional movements performed [13–15].”
Method
Cited by
Cereatti, A., Gurchiek, R., Mündermann, A., Fantozzi, S., Horak, F., Delp, S., & Aminian, K. (2024) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2024.112225 · Cited by 79
Tibial bone forces can be monitored using shoe-worn wearable sensors during running
Elstub, L. J., Nurse, C. A., Grohowski, L. M., Völgyesi, P., Wolf, D. N., & Zelik, K. E. (2022) · Journal of Sports Sciences · doi:10.1080/02640414.2022.2107816 · Cited by 41
“However, the optimization of IMU calibration (Choe et al., 2019; Favre et al., 2008), placement (Niswander et al., 2020), and processing (Gui et al., 2015; Sabatelli et al., 2013) has led to improvements in accuracy of kinematic estimates compared with 3D motion capture during gait (Lebleu et al.,…”
MethodNiswander, W., & Kontson, K. L. (2021) · Sensors · doi:10.3390/s21123989 · Cited by 45
“Although other locations on the upper thigh and lower torso were identified as common locations for IMU sensors in previous work [23], Panebianco et al.”
MethodSelf-citationRattanakoch, J., Samala, M., Limroongreungrat, W., Guerra, G., Tharawadeepimuk, K., Nanbancha, A., Niamsang, W., Kerdsomnuek, P., & Suwanmana, S. (2023) · Sensors · doi:10.3390/s23031738 · Cited by 34
Co-simulation of human digital twins and wearable inertial sensors to analyse gait event estimation
Uhlenberg, L., Derungs, A., & Amft, O. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1104000 · Cited by 36
“Practical deployment of wearable motion analysis often involves iterative physical testing to optimise and correct sensor positioning (Förster et al., 2009; Niswander et al., 2020), which is tedious due to repeated measurements and prone to error due to, e.”
Method
Metadata
- Authors
- Niswander, W., Wang, W., & Kontson, K.
- Affiliations
- United States Food and Drug Administration (US)
- Corresponding author
- Kontson, Kimberly
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-10-22
- Volume
- 20
- Issue
- 21
- Pages
- 5993
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC7660215
- OpenAlex
- W3094382181
- Cited by
- 116
- References
- 39
- Citations by year
- 2026: 32 · 2025: 23 · 2024: 23 · 2023: 18 · 2022: 13 · 2021: 7
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- U.S. Food and Drug Administration (CPI)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Keywords
- inertial measurement unit, sensor placement, lower limb joint kinematics, hip joint angle, knee joint angle, ankle joint angle, Timed Up and Go test, wearable sensors, gait analysis, measurement accuracy, functional movement, rehabilitation
- MeSH terms
- Wearable Electronic Devices, Gait Analysis, Biomechanical Phenomena, Exercise Test, Humans, Range of Motion, Articular, Walking, Lower Extremity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimization of IMU Sensor Placement for the Measurement of Lower Limb Joint Kinematics. https://app.cochat.ai/papers/10.3390/s20215993
- The paper
- Niswander, W., Wang, W., & Kontson, K. (2020). Optimization of IMU Sensor Placement for the Measurement of Lower Limb Joint Kinematics. Sensors. https://doi.org/10.3390/s20215993
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.