CoChat

Determination of carbon and nitrogen contents in Alfisols, Oxisols and Ultisols from Africa and Brazil using NIRS analysis: Effects of sample grinding and set heterogeneity

Open access
Brunet, Didier, Barthès, Bernard G., Chotte, Jean-Luc, Feller, Christian · 2007 · Geoderma
Cited by 182

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Abstract

Abstract Near infrared reflectance spectroscopy (NIRS) is a rapid and low-cost method that has been reported to provide accurate prediction of soil total carbon (Ct) and nitrogen (Nt) contents. However, methodological aspects such as sample preparation and set homogeneity have not been addressed extensively. The main objective of the paper was to assess how NIRS determination of Ct and Nt was affected by sample preparation (0.2 mm grinding vs. 2 mm sieving) and set heterogeneity (i.e. using the total set vs. texture or localised sets). The study was performed on a range of African and Brazilian Alfisols, Oxisols and Ultisols (297 samples, with 6–80% clay). The total set could be divided into a coarse-textured set, including samples from Burkina Faso and Benin mainly, and a clayey set, including samples from Brazil mainly. Calibration and validation procedures were carried out within the total set and within each of the two texture sets and the three localised sets (Burkina Faso, Benin, and Brazil). Prediction of Ct using first derivatives with SNV (standard normal variate) scatter correction, which was the most appropriate spectrum preprocessing method, was in general more accurate for ground than for sieved samples. The difference was decisive when the determination was carried out on the localised clayey set, moderate on total and texture sets, and unclear on localised coarse-textured sets. Prediction of Nt was less clearly affected by sample preparation, though grinding was useful for the localised clayey set and harmful for localised coarse-textured ones. Thus the effect of sample preparation on prediction accuracy depended on soil texture, which may explain the contradictory results reported in the literature, often referring to narrow soil ranges. Using the same preprocessing method, the accuracy of Ct prediction generally increased with set homogeneity (i.e. from total to texture sets and from texture to localised sets), providing that clayey sets were ground. This agreed with deductions drawn from comparison between earlier studies carried out with either homogeneous or heterogeneous sets. The effect of set homogeneity on Nt prediction could not, however, be clearly demonstrated by this study. In conclusion, the study confirmed the interest of NIRS for the rapid and accurate determination of Ct and Nt, especially when homogeneous sets including ground samples were used.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.geoderma.2007.01.007

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

Metadata

Authors
Brunet, D., Barthès, B. G., Chotte, J.-L., & Feller, C.
Venue
Geoderma
Publisher
Elsevier BV
Published
2007-04
Volume
139
Issue
1-2
Pages
106-117
ISSN
0016-7061 (ISSN-L)
OpenAlex
W2060896115
Cited by
182
References
32
FWCI
9.06
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.