The DOI matches its Crossref record.
A pilot study to assess the safety and efficacy of carbon dioxide insufflation during colorectal endoscopic submucosal dissection with the patient under conscious sedation
Open accessAbstract
BACKGROUND Endoscopic submucosal dissection (ESD) is accepted as one of the treatments for en bloc resection of large superficial colorectal lesions. This procedure is performed by using air insufflation, is time consuming, and is associated with severe abdominal discomfort. The safety and efficacy of carbon dioxide (CO(2)) insufflation during colonoscopy already has been assessed in some trials. OBJECTIVE To assess the safety and efficacy of CO(2) insufflation instead of air insufflation during colorectal ESD with the patient under conscious sedation. DESIGN A case-control series with a historical control. PATIENTS A total of 35 consecutive patients were enrolled in this study. Another 35 consecutive patients who previously received colorectal ESDs by using air insufflation were included as a historical control. INTERVENTIONS Arterial partial pressure of CO(2) (pCO(2)) was measured before and after each procedure with the total dose of midazolam used as an index of abdominal discomfort. MAIN OUTCOME MEASUREMENTS AND RESULTS The mean (standard deviation [SD]) operation time was 90 +/- 57 minutes in the CO(2) group and 100 +/- 80 minutes in the control group (not significant). In the CO(2) group, the mean (SD) dose of midazolam was significantly lower than that of the control group; 5.6 +/- 4.9 mg and 9.7 +/- 5.9 mg, respectively (P = .005). Blood analysis revealed a slight pCO(2) elevation in the CO(2) group; however, only 2 patients complained of mild abdominal discomfort. LIMITATIONS Abdominal discomfort and pCO(2) were not evaluated in the control group. CONCLUSIONS This study strongly suggests that CO(2) insufflation is safe and effective during lengthy colonic endoscopic procedures, eg, ESD, with the patient under conscious sedation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pennazio, M., Spada, C., Eliakim, R., Keuchel, M., May, A., Mulder, C., Rondonotti, E., Adler, S., Albert, J., Baltes, P., et al. (2015) · Endoscopy · doi:10.1055/s-0034-1391855 · Cited by 894
A prospective, multicenter study of 1111 colorectal endoscopic submucosal dissections (with video)
Saito, Y., Uraoka, T., Yamaguchi, Y., Hotta, K., Sakamoto, N., Ikematsu, H., Fukuzawa, M., Kobayashi, N., Nasu, J., Michida, T., et al. (2010) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2010.08.004 · Cited by 787
Self-citationJGES guidelines for colorectal endoscopic submucosal dissection/endoscopic mucosal resection
Tanaka, S., Kashida, H., Saito, Y., Yahagi, N., Yamano, H., Saito, S., Hisabe, T., Yao, T., Watanabe, M., Yoshida, M., et al. (2015) · Digestive Endoscopy · doi:10.1111/den.12456 · Cited by 597
Self-citationRondonotti, E., Spada, C., Adler, S., May, A., Despott, E., Koulaouzidis, A., Panter, S., Domagk, D., Fernandez-Urien, I., Rahmi, G., et al. (2018) · Endoscopy · doi:10.1055/a-0576-0566 · Cited by 444
Tanaka, S., Kashida, H., Saito, Y., Yahagi, N., Yamano, H., Saito, S., Hisabe, T., Yao, T., Watanabe, M., Yoshida, M., et al. (2020) · Digestive Endoscopy · doi:10.1111/den.13545 · Cited by 431
Self-citation
Metadata
- Authors
- Saito, Y., Uraoka, T., Matsuda, T., Emura, F., Ikehara, H., Mashimo, Y., Kikuchi, T., Kozu, T., & Saito, D.
- Venue
- Gastrointestinal Endoscopy
- Publisher
- Elsevier BV
- Published
- 2007-03
- Volume
- 65
- Issue
- 3
- Pages
- 537-542
- ISSN
- 0016-5107 (ISSN-L)
- OpenAlex
- W2007654599
- Cited by
- 201
- References
- 0
- FWCI
- 7.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A pilot study to assess the safety and efficacy of carbon dioxide insufflation during colorectal endoscopic submucosal dissection with the patient under conscious sedation. https://app.cochat.ai/papers/10.1016/j.gie.2006.11.002
- The paper
- Saito, Y., Uraoka, T., Matsuda, T., Emura, F., Ikehara, H., Mashimo, Y., Kikuchi, T., Kozu, T., & Saito, D. (2007). A pilot study to assess the safety and efficacy of carbon dioxide insufflation during colorectal endoscopic submucosal dissection with the patient under conscious sedation. Gastrointestinal Endoscopy. https://doi.org/10.1016/j.gie.2006.11.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.