The DOI matches its Crossref record.
Esophagogastric junction distensibility assessed with an endoscopic functional luminal imaging probe (EndoFLIP)
Open accessAbstract
Background Increased esophagogastric junction (EGJ) compliance is a key abnormality in GERD leading to increased volumes of reflux. To date, EGJ distensibility has been measured only with investigational barostatbased prototype devices. Objectives The aim of the study was to test the endoscopic functional luminal imaging probe (EndoFLIP), a new commercially available technology designed to measure intraluminal distensibility, by assessing the EGJ of GERD patients and controls. Design Prospective case-control series. Setting Tertiary referral center. Subjects Twenty GERD patients and 20 controls studied during a routine esophagogastroduodenoscopy. Methods The EndoFLIP was passed through the endoscopic instrumentation channel and positioned across the EGJ. The EndoFLIP uses impedance planimetry to measure 16 cross-sectional areas (CSA) along with the corresponding intrabag pressure within a 4.6-cm cylindrical segment of a fluid-filled bag. Main Outcome Measurement EGJ distensibility was assessed with 10- to 40-mL volume-controlled distentions. Results In both groups, the least distensible locus at the EGJ was usually at the hiatus. As a group, GERD patients exhibited two- to threefold increased EGJ distensibility compared with controls, particularly at 20- to 30-mL distention volumes, values quantitatively similar to previous measurements with barostat-based devices. The endoscopic estimation of EGJ distensibility, the flap valve grade, correlated poorly with EndoFLIP measurements. Limitations Heterogeneity of GERD patients. Conclusions Measurement of EGJ distensibility with EndoFLIP is feasible during clinical endoscopy. Stratifying GERD patients according to this physiological parameter may facilitate the identification of patient subgroups responsive or unresponsive to medical or surgical treatments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pathophysiology of Eosinophilic Esophagitis
O’Shea, K. M., Aceves, S. S., Dellon, E. S., Gupta, S. K., Spergel, J. M., Furuta, G. T., & Rothenberg, M. E. (2018) · Gastroenterology · doi:10.1053/j.gastro.2017.06.065 · Cited by 502
Esophageal motor dysfunctions in gastroesophageal reflux disease and therapeutic perspectives
Lin, S., Li, H., & Fang, X. (2019) · Journal of Neurogastroenterology and Motility · doi:10.5056/jnm19081 · Cited by 52
Metadata
- Authors
- Kwiatek, M. A., Pandolfino, J. E., Hirano, I., & Kahrilas, P. J.
- Venue
- Gastrointestinal Endoscopy
- Publisher
- Elsevier BV
- Published
- 2010-08
- Volume
- 72
- Issue
- 2
- Pages
- 272-278
- ISSN
- 0016-5107 (ISSN-L)
- OpenAlex
- W2045323265
- Cited by
- 251
- References
- 0
- FWCI
- 11.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Esophagogastric junction distensibility assessed with an endoscopic functional luminal imaging probe (EndoFLIP). https://app.cochat.ai/papers/10.1016/j.gie.2010.01.069
- The paper
- Kwiatek, M. A., Pandolfino, J. E., Hirano, I., & Kahrilas, P. J. (2010). Esophagogastric junction distensibility assessed with an endoscopic functional luminal imaging probe (EndoFLIP). Gastrointestinal Endoscopy. https://doi.org/10.1016/j.gie.2010.01.069
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.