Automated polyp detection in the colorectum: a prospective study (with videos)
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND AIMS Adenoma detection is a highly personalized task that differs markedly among endoscopists. Technical advances are therefore desirable for the improvement of the adenoma detection rate (ADR). An automated computer-driven technology would offer the chance to objectively assess the presence of colorectal polyps during colonoscopy. We present here the application of a real-time automated polyp detection software (APDS) under routine colonoscopy conditions. METHODS This was a prospective study at a university hospital in Germany. A prototype of a novel APDS ("KoloPol," Fraunhofer IIS, Erlangen, Germany) was used for automated image-based polyp detection. The software functions by highlighting structures of possible polyp lesions in a color-coded manner during real-time colonoscopy procedures. Testing the feasibility of APDS deployment under real-time conditions was the primary goal of the study. APDS polyp detection rates (PDRs) were defined as secondary endpoints provided that endoscopists' detection served as criterion standard. RESULTS The APDS was applied in 55 routine colonoscopies without the occurrence of any clinically relevant adverse events. Endoscopists' PDRs and ADRs were 56.4% and 30.9%, respectively. The PDRs and ADRs of the APDS were 50.9% and 29.1%, respectively. The APDS detected 55 of 73 polyps (75.3%). Smaller polyp size and flat polyp morphology were correlated with insufficient polyp detection by the APDS. CONCLUSION Computer-assisted automated low-delay polyp detection is feasible during real-time colonoscopy. Efforts should be undertaken to improve the APDS with respect to smaller and flat shaped polyps. (Clinical trial registration number: NCT02838888.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adenoma detection rate and risk of colorectal cancer and death
Corley, D. A., Jensen, C. D., Marks, A. R., Zhao, W. K., Lee, J. K., Doubeni, C. A., Zauber, A. G., de Boer, J., Fireman, B. H., Schottinger, J. E., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1309086 · Cited by 2,270
Quality indicators for colonoscopy
Rex, D. K., Schoenfeld, P. S., Cohen, J., Pike, I. M., Adler, D. G., Fennerty, M. B., Lieb, J. G., Park, W. G., Rizk, M. K., Sawhney, M. S., et al. (2015) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2014.07.058 · Cited by 1,764
Factors influencing the miss rate of polyps in a back-to-back colonoscopy study
Leufkens, A., van Oijen, M., Vleggaar, F., & Siersema, P. (2012) · Endoscopy · doi:10.1055/s-0031-1291666 · Cited by 375
Cited by
Kamiński, M., Hassan, C., Bisschops, R., Pohl, J., Pellisé, M., Dekker, E., Ignjatovic-Wilson, A., Hoffman, A., Longcroft-Wheaton, G., Heresbach, D., et al. (2014) · Endoscopy · doi:10.1055/s-0034-1365348 · Cited by 433
Bisschops, R., East, J. E., Hassan, C., Hazewinkel, Y., Kamiński, M. F., Neumann, H., Pellisé, M., Antonelli, G., Bustamante Balen, M., Coron, E., et al. (2019) · Endoscopy · doi:10.1055/a-1031-7657 · Cited by 340
Artificial Intelligence in Colorectal Cancer Screening, Diagnosis and Treatment. A New Era
Mitsala, A., Tsalikidis, C., Pitiakoudis, M., Simopoulos, C., & Tsaroucha, A. K. (2021) · Current Oncology · doi:10.3390/curroncol28030149 · Cited by 271
Application of artificial intelligence in gastroenterology
Yang, Y. J., & Bang, C. S. (2019) · World Journal of Gastroenterology · doi:10.3748/wjg.v25.i14.1666 · Cited by 263
Hashimoto, R., Requa, J., Dao, T., Ninh, A., Tran, E., Mai, D., Lugo, M., El-Hage Chehade, N., Chang, K. J., Karnes, W. E., et al. (2020) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2019.12.049 · Cited by 236
Metadata
- Authors
- Klare, P., Sander, C., Prinzen, M., Haller, B., Nowack, S., Abdelhafez, M., Poszler, A., Brown, H., Wilhelm, D., Schmid, R. M., von Delius, S., & Wittenberg, T.
- Venue
- Gastrointestinal Endoscopy
- Publisher
- Elsevier BV
- Published
- 2019-03
- Volume
- 89
- Issue
- 3
- Pages
- 576-582.e1
- ISSN
- 0016-5107 (ISSN-L)
- OpenAlex
- W2897749869
- Cited by
- 100
- References
- 3
- FWCI
- 5.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.